Technical data
Feature
Resistance to forced entry
Housing
Dead bolt
Operating temperature
Bolt throw
Installation position
Rebate gap
Assembly tolerance of the sensor
Maximum preload unlocking
EltVTR
NFS 61937
Compatibility with other products
Electrical data
Feature
Operating voltage
Max. current consumption in continuous
operation
Max. current consumption with motor operation
(approx. 1 s)
Max. contact loading capacity of the armature
Max. contact loading capacity of the door contact 25 V DC / 100 mA ohmic load
Fail-unlocked operating principle
Characteristic
5000 N
Stainless steel, laser-welded
and uncoated
Steel
-15°C . . . +50°C
10 mm
universal
3 mm (2 mm – 4.5 mm)
±4.5 mm vertically
5000 N
effeff Electric electric strike
351U80
12 V DC 24 V DC 48 V DC
+/– 10 %
+/– 10 % +/– 10 %
Regulated DC voltage
480 mA
270 mA 150 mA
880 mA
520 mA 270 mA
25 V / 500 m A