Torsion-free installation: The electric strike 351M80 must be installed free of
torsion. Check whether the door stops properly and does not show any signs of
warpage before mounting.
Observe the tolerances for the voltage supply: The operating voltage meas-
ured on The electric strike 351M80 at rated current must lie within the specified
tolerance limits. Damage and malfunctions will occur if the tolerance limits are
exceeded or undercut.
Check The electric strike 351M80 after mounting: The electric strike 351M80
must move with consistent ease in all functions. The bolt must move easily when
closing. An inconsistent or sluggish movement of the bolt can indicate a mount-
ing error or distorted installation.
Installation in a normal position for locks: Large leverage forces arise on doors,
whereby The electric strike, door frame and door leaf can be damaged when the
installation position is incorrect. The electric strike 351M80 must be installed as far
away from the door hinge as possible.