I N S T A L L A T I O N I N S T R U C T I O N S F L U S H C E I L I N G I N S T A L L A T I O N ( C O N T I N U E D )
7a. Once the frame is mounted, the safety rope for the infrared
panel must be fitted. One end of the rope is already fixed to one
corner of the frame at the factory. Now pull the loose side of the
rope through the two eyelets on the back of the panel and fix it
to the opposite corner of the frame.
7. Now you can connect the panel.
9. In addition, the tightness of the panel of the click locks can
be adjusted slightly. With a screwdriver you can tighten the
mounting brackets by turning it to the right so that the panel is
tighter. This helps to avoid expansions of the device.
14
7b. Use the enclosed screw terminal and fix the cable. The in-
frared heating device is secured to the frame by a steel cable.
8. Finally, carefully press the panel into the frame. Once the
click locks are engaged, you can release the panel.
10. If a gap is created between the mounting frame and the
ceiling or wall during installation, it can be repaired and paint-
ed over with acrylic.