Unit Door; Ventilation Of The Kitchen Unit; Changing Over Door Hinges - V-ZUG Magnum 2 60i eco Serie Notice D'installation

Masquer les pouces Voir aussi pour Magnum 2 60i eco Serie:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Unit door

D
E
(mm)
(mm)
Magnum
2
60i
1772
560
eco,
Jumbo
1788
570
60i, Iglu
60i
Ideal 60i
874
560
890
570
The specified energy consumption applies to a unit depth of
560 mm. The appliance will work properly at a unit depth of 550
mm, but at a slightly higher energy consumption.
u In the case of Side-by-Side instal-
lation, two appliances next to one
another, build the appliances into
separate kitchen units.*
u Check the wall thickness of the adjoining cabinets: it must
be min. 16 mm thick.
u Only install the appliance in robust, stable kitchen units.
Secure the units against tipping.
u Align the kitchen unit using a spirit level and marking square
and if necessary compensate with shims.
u Ensure that the floor and walls of the unit are at right angles
to one another.
6 Unit door
-
One door is required for the kitchen unit.
-
The door must be minimum 16 mm and maximum 19 mm
thick.
-
There must be a gap of minimum 3 mm width between the
door and the unit door located above it (if one exists).
-
The width of the unit door depends on the style of the
kitchen and the gap size between the door panels of the
cabinet. Generally, there should remain a vertical gap of
3 mm between the unit doors.
-
If other cabinets are present, the top edge of the unit door
should be on a level with the doors of the adjoining units.
-
The unit door must be planar and mounted stress-free.
NOTICE
Risk of damage from over-heavy unit door!
If the unit door is too heavy, damage to the hinges and resulting
impairment of function cannot be excluded.
u Before mounting the unit door, make sure that the door does
not exceed the approved unit door weight.
Appliance model
Magnum 2 60i eco, Jumbo 60i,
Iglu 60i
Ideal 60i
22
F (mm)
G
H
(mm)
(mm)
min.
550,
min.
max.
recom-
500
19
mended:
560
min.
550,
min.
max.
recom-
500
19
mended:
560
Maximum
cabinet
door weight (kg)
26
16

7 Ventilation of the kitchen unit

*
-
There must be an effective ventilation shaft of at least
200 cm
per appliance at the air inlet
2
Fig. 3 (B) vent.
-
The principle applies that the larger the ventilation shaft, the
more energy-saving the operation of the appliance.
-
The upper ventilation shaft can either be positioned directly
above the appliance with an optional ventilation grille
Fig. 4 (C) , close to the ceiling above the unit Fig. 4 (D) or
as an air outlet opening in a false ceiling

8 Changing over door hinges

NOTICE
Risk of damage due to condensation and colliding doors!
If you are installing V-Zug Side-by-Side (SBS) appliances
next to each other:
u Install the appliances so that the doors open outwards.
Switch the door hinges, if necessary.
Fig. 3 (A) and outlet
Fig. 4 (E) .
* Depending on model and options
Fig. 3
Fig. 4

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Jumbo 60i serieIglu 60i serieIdeal 60i serie

Table des Matières