Trouble Shooting - Parkside PHD 150 C2 Traduction Du Mode D'emploi D'origine

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Trouble shooting

Problem
Possible cause
Standard Vario nozzle (18)
is soiled
Severe pres-
sure fluctua-
tions
Standard Vario nozzle (18)
is blocked
ON / OFF switch (10) is
turned off
Pressure
Damaged power supply
cleaner is not
cable (6)
operating
Mains fault
Air trapped in the pressure
Pressure clean-
cleaner
er does not
generate any
Drop in the water mains
pressure
pressure
Connections not fitted cor-
rectly
Leaks in the
water system
Water connection (9) leaks
Remedy
Rinse the standard Vario nozzle (18)
with water. If required, clean the nozzle
bore hole with a needle (see chapter en-
titled cleaning).
Remove the nozzles (17/18) or the wash
brush (19) and ensure that the water can
discharge from the jet gun (1) unimped-
ed. In other words, the device is working
perfectly. The turbo dirt blaster (17) and
the rotating wash brush (18) do not nor-
mally get blocked.
Check ON / OFF switch (10)
Switch off the equipment and disconnect
from the mains. Check power supply
cable (6) for damage. If necessary have
the power supply cable (6) replaced by
a qualified electrician.
Check the electrical system for conform-
ity with the data on the rating plate.
Switch on the equipment with the jet gun
and with no nozzle until bubble-free wa-
ter comes out.
Check the water mains.
Switch off the equipment and disconnect
from the mains. Reconnect the equipment
to the water pipes (cf. "Initial Operation/
Set-Up")
Switch off the equipment and disconnect
from the mains. Replace the water con-
nection (9) inc. gasket (cf. "Spare Parts")
GB