Specifications - Osburn OP00030 Manuel D'opération

Masquer les pouces Voir aussi pour OP00030:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

SPECIFICATIONS

Model
Fuel Type
1
Recommended heating area (sq. ft
Hopper capacity
Maximum burn time
2
Recommended chimney diameter
Flue outlet diameter
Type of chimney
Approved for alcove installation
Approved for mobile home installation
Shipping weight (without option)
Appliance weight (without option)
Baffle material
Type of door
Type of glass
Blower
Noise level at 6 feet
1
Grades of pellet fuel are determined by organizations such as Pellet Fuels Institute (PFI), ENplus and CANplus.
2
Recommended heating area and maximum burn time may vary subject to location in home, chimney draft, heat loss factors, climate, fuel type, feed
rate, fuel level, and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a
minimum acceptable temperature considering that the space configuration and the presence of heat distribution systems have a significant impact
in making heat circulation optimum.
Mobile home (Canada) or manufactured home (USA): The US department of Housing and Urban Development describes "manufactured homes"
3
better known as "mobile homes" as followed; buildings built on fixed wheels and those transported on temporary wheels/axles and set on a
permanent foundation. In Canada, a mobile home is a dwelling for which the manufacture and assembly of each component is completed or
substantially completed prior to being moved to a site for installation on a foundation and connection to service facilities and which conforms to the
CAN/CSA-Z240 MH standard.
Page 6
3000 (OP00030)
Premium grade or better wood pellets
)
500 - 2 200 pi
.
2
55 lb (25 kg)
45 hours
3 in. or 4 in (see installation manual).
3 in. (80 mm)
ULC/ORD-C441, CAN/ULC S609
UL 641 (TYPE L)
Yes
Yes
3
367 lb (167 Kg)
324 lb (147 Kg)
Stainless Steel
Simple, glass with cast iron frame
Ceramic glass
Included (176 CFM)
47.6 dB (A) ± 3 dB (A)
59 dB (A) ± 3 dB (A)
(46 à 185 m
)