4.7.2

With active "safe standstill" function

Safety instructions for the installation of the "safe standstill" function
Only qualified personnel are permitted to install and set up the "Safe standstill"
ƒ
function.
All safety-relevant cables (e. g. control cable for the safety relay, feedback contact)
ƒ
outside the control cabinet must be protected, for instance, by a cable duct. Short
circuits between the single cables must be ruled out!
Wiring of the safety relay K
ƒ
absolutely vital.
The electrical reference point for the coil of the safety relay K
ƒ
with the protective conductor system (DIN EN 60204-1 paragraph 9.4.3). Only this
measure guarantees that the operation is protected against earth faults.
Internal voltage supply
For supplying the digital inputs (X5/E1 ... X5/E5, X5/ST1), a freely assignable digital
ƒ
output (e. g. X5/A1) must be firmly applied to HIGH level.
For supplying the analog inputs (X6/1, X6/2 and X6/3, X6/4), a freely assignable
ƒ
analog output (e. g. X6/63) must be firmly applied to HIGH level.
+5 V
+
K
SR
X11 K31 K32 33 34
X5 28 E1 E2 E3 E4
S1
S2
IN1 IN2 IN3 IN4
Z1
Fig.4-26
EDKVS9332X DE/EN/FR 2.0
with insulated wire end ferrules or rigid cables is
SR
GND2
E5
39
A1
Wiring of digital and analog inputs/outputs with active "safe standstill" function and internal
voltage source
S1
Pulse inhibit deactivation (1st disconnecting path)
S2
Controller enable (2nd disconnecting path)
Z1
Programmable logic controller (PLC)
The PLC takes over the automatic cyclic monitoring of the "safe standstill" function
X5/A4 Feedback via a digital output (e. g. DIGOUT4)
NO contact or NC contact
Load
Z
Minimum wiring required for operation
Terminal assignment in the Lenze setting:  180
Electrical installation
Wiring of the control connections
With active "safe standstill" function
+24V
1
2
3
X3
4
http://www.DataSheet4U.net/
5
6
A2 A3 A4 ST1ST2 59
X6
Z
Z
must be connected
SR
GND1
GND1
242R
3.3nF
1
2
3
4
7
62 63
AOUT2
AIN1
AIN2
AOUT1
1
2
3
4
7
AOUTx
10k
10k
9300std074
4
7
175