Features of the connection for motor temperature monitoring:
Pins X7/8, X7/9 from resolver input (X7), or
pins X8/8, X8/5 from incremental encoder input (X8)
Connection
Tripping point
Comments
U, V, W
0.5...0.6 Nm
T1, T2
4.4...5.3 lb-in
Fig.4-8
Cable cross-sections
9300
Type
EVS9321-xx
EVS9322-xx
EVS9323-xx
EVS9324-xx
EVS9325-xx
EVS9326-xx
EDKVS9332X DE/EN/FR 2.0
Basic devices in the power range 0.37 ... 11 kW
Linear KTY temperature sensor
Warning: adjustable
Error (TRIP): fixed at 150 °C
Monitoring is not active in the Lenze setting.
The KTY temperature sensor is monitored with regard to interruption and short
circuit.
2
PE
T1T2
U V W
1
0
Motor connection with KTY thermal sensor
Motor cable
Shield sheet
Securely clamp shield of motor cable with the lugs
U, V, W
Motor cable connection
Observe correct polarity. Observe maximum length of motor cable.
Cable cross-sections up to 4 mm
Cable cross-sections > 4 mm
2
[mm
]
1
1
1
1.5
4
6
Electrical installation
Motor connection
http://www.DataSheet4U.net/
2
: Use wire end ferrules for flexible cables
2
: Use pin-end connectors
Cable cross-sections U, V, W, PE
4
9300vec122
[AWG]
18
18
18
16
12
10
147