Resolver At X7 - Lenze EVS9321 Instructions De Montage

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4
Electrical installation
Wiring of the feedback system

Resolver at X7

4.9.2
Resolver at X7
Technical data
Field
Resolver type recommended
Number of pole pairs of the resolver 1
Transmission ratio
Evaluation procedure
Max. output voltage
Max. current consumption
Max. impedance [Z]
Output frequency
Connection at drive controller
Monitoring
Wiring
Fig.4-32
Assignment of the 9-pole Sub-D socket (X7) at the controller
Pin
Signal
0.5 mm
186
Values
Receiver
0.3
Voltage application in the sine and cosine winding
± 10 V
50 mA per winding
500 Ω per winding
4 kHz
9-pole Sub-D socket
Monitoring with regard to open circuit of the resolver and the resolver
cable (configurable)
< 50 m
KTY
Resolver connection
Cores twisted in pairs
1
2
3
+REF
-REF
GND
2
(AWG 20)
X7
+REF
1
-REF
2
3
+COS
4
-COS
5
http://www.DataSheet4U.net/
+SIN
6
-SIN
7
+KTY
8
-KTY
9
4
5
6
+COS
-COS
+SIN
0.14 mm
9300STD331
7
8
9
-SIN
+KTY
-KTY
2
(AWG 26)
EDKVS9332X DE/EN/FR 2.0
datasheet pdf - http://www.DataSheet4U.net/

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Evs9332

Table des Matières