Appliances Equipped With Casters; Swivel Caster Installation; Electrical Connections; Ventilation And Clearance - Garland XG24 Installation Et Fonctionnement

Table des Matières

Publicité

INSTALLATION continued

Appliances Equipped with Casters:

1. The installation shall be made with a connector that
complies with the Standard for Connectors for Moveable
Gas Appliances, ANSI Z21.69 or latest edition, addenda
Z21.69a-1989, and a quick-disconnect device that
complies with the Standard for Quick Disconnects for Use
with Gas Fuel. ANSI Z21.41 or latest edition.
2. The front casters on the appliance are equipped with
brakes to limit the movement of the appliance without
placing any strain on the connector or quick-disconnect
device or its associated piping.
3. Please be aware; required restraint is attached to a
bracket (which is located on the rear caster closest to the
gas connection), and if disconnection of the restraint
is necessary; be sure to reconnect the device after the
appliance has been returned to its original position.

Swivel Caster Installation

Prior to installation, the four casters, supplied loose with the
grill, must be securely located on the underside of the base.
The casters fitted with a brake must be located at the front of
the grill.
1. Carefully remove the top and side packaging leaving the
grill on shipping pallet.
DO NOT REMOVE THE TIES SECURING THE PLATEN ARMS
TO THE GRILL TOWEL BAR.
2. Raise the grill vertically off the pallet to a comfortable
working height and install the casters. DO NOT TIP THE
GRILL ON ITS BACK OR SIDE. If a truck lift is used, be
careful when inserting the lifting arms under the grill as
the gas inlet elbow is protruding in the center of the base.
WARNING - GRILL WEIGHT IS APPROXIMATELY 800 LBS –
USE CAUTION
3. Install the casters as shown below. The two casters with
brakes go on the front, and the two without on the rear.
Page 8
WITH
BRAKE
NOTE: CASTERS MUST BE THREADED INTO GRILL BASE
LEAVING APPROXIMATELY ONE INCH OF EXPOSED
THREAD. THIS IS THE STARTING POINT FOR LEVELLING THE
GRILL AFTER IT IS IN POSITION.

Electrical Connections:

All electrically operated appliances must be electrically
grounded in accordance with local codes; or in the absence
of local codes, with the latest edition of National Wiring
Regulations. A wiring diagram is located on the rear panel of
the grill. See rating plate in rear of grill, or lower front panel
for proper voltages.

Ventilation and Clearance:

One of the most important considerations of efficient grill
operation is proper ventilation and air supply. Insure the
grill is installed so the products of combustion are removed
efficiently and the ventilation system does not produce
drafts that interfere with proper burner operation.
Proper operation of exhaust fans (speed, rotation and
adjustment) is essential. In addition to the exhaust system
the make-up air system, (HVAC), for the kitchen is the
air supply for the combustion air for the burners. Proper
incoming air is essential for all gas operated equipment. Poor
incoming make-up will cause inefficient burner operation,
delayed ignition and possible burner failure.
Any ventilation system will break down if improperly
maintained. The duct system, the hood, and the filters must
be cleaned on a regular basis and kept grease free.
The room containing the grill is required to have a
permanent air vent. The minimum effective area of the vent
shall be 0.7 in.² per kW. Air vents shall be of such a size to
compensate for the effects of any extract fan in the premises.
WITHOUT
BRAKE
Part # 4517124 Rev. 7 (08/17/11)

Publicité