PROGRAMMING

To Change the Alarm Volume:

1. Press and hold
for three, (3) seconds. "ENTER CODE" is
displayed.
2. Using the Product buttons, 0-9 enter the code, (1251).
"ENTER CODE **** " is displayed.
3. Press
to enter the Programming Mode.
"PROGRAMMING MODE MENU ITEMS" is displayed.
4. Press
two, (2) times. "PROGRAMMING MODE SYSTEM
SETUP" is displayed.
5. Press
three, (3), times. "ALARM VOLUME LOW (or
HIGH)" is displayed.
6. Use
or
to change the Alarm Volume to either Low
or High.
7. Press
to save the changes.
8. Press
to return to "PROGRAMMING MODE SYSTEM
SETUP"
9. Press
again to exit.

To Change the Key Chirp:

To turn key chirp on or off in programing mode only.
1. Press and hold
for three, (3) seconds. "ENTER CODE" is
displayed.
2. Using the Product buttons, 0-9 enter the code, (1251).
"ENTER CODE **** " is displayed.
3. Press
to enter the Programming Mode.
"PROGRAMMING MODE MENU ITEMS" is displayed.
4. Press
two, (2) times. "PROGRAMMING MODE SYSTEM
SETUP" is displayed.
5. Press
four, (4), times. "KEY CHIRP ON (or OFF" is
displayed.
6. Use
or
to change the key chirp to either ON or OFF.
7. Press
to save the changes.
8. Press
to return to "PROGRAMMING MODE SYSTEM
SETUP"
9. Press
again to exit.

To Change Upper Set Temperature:

1. Press and hold
for three, (3) seconds. "ENTER CODE" is
displayed.
2. Using the Product buttons, 0-9 enter the code, (1251).
"ENTER CODE **** " is displayed.
Part # 4517124 Rev. 7 (08/17/11)
continued
3. Press
to enter the Programming Mode.
"PROGRAMMING MODE MENU ITEMS" is displayed.
4. Press
two, (2) times. "PROGRAMMING MODE SYSTEM
SETUP" is displayed.
5. Press
five, (5), times to display "UPPER SET TEMP". The
default temperature value is 425F (218C).
6. Press
or use
and
temperature value (typically the most used in cooking).
The temp range is 300 – 425F.
7. Press
to save the changes.
8. Press
to return to "PROGRAMMING MODE SYSTEM
SETUP"
9. Press
again to exit.

To Change Grill Set Temperature:

1. Press
and hold for three, (3) seconds. "ENTER CODE" is
displayed.
2. Using the Product buttons, 0-9 enter the code, (1251).
"ENTER CODE **** " is displayed.
3. Press
to enter the Programming Mode.
"PROGRAMMING MODE MENU ITEMS" is displayed.
4. Press
two, (2) times. "PROGRAMMING MODE SYSTEM
SETUP" is displayed.
5. Press
six, (6), times to display "GRILL SET TEMP". The
default temperature value is 350F (177C).
6. Press
to accept or use
a desired temperature value (typically the most used in
cooking). The temp range is 275 – 375F.
7. Press
to save the changes.
8. Press
to return to "PROGRAMMING MODE SYSTEM
SETUP"
9. Press
again to exit.

To Change Probe Calibration - Upper:

1. Press and hold
for three, (3) seconds. "ENTER CODE" is
displayed.
2. Using the Product buttons, 0-9 enter the code, (1251).
"ENTER CODE **** " is displayed.
3. Press
to enter the Programming Mode.
"PROGRAMMING MODE MENU ITEMS" is displayed.
4. Press
two, (2) times. "PROGRAMMING MODE SYSTEM
SETUP" is displayed.
to change the key to a desired
and
to change the key to
Page 25