CALIBRATION continued
Probe Locations:
The grill's thermocouple probes are located on each section of the lower grill plate in the center of the cooking zone as shown
in the diagram below. Each upper platen has one thermocouple probe in the center.
5.75"
22.5"
11.25"
24"
12"
MODEL XG24
Page 30
11.5"
11.5"
5.75"
TOP
PLATEN
(2 PLACES)
GRILL PLATE
6.09"
6.09"
24"
11.5"
5.75"
22.5"
11.25"
24"
12"
6.09"
18"
11.5"
11.5"
5.75"
5.75"
TOP
PLATEN
(3 PLACES)
GRILL PLATE
6.09"
36"
MODEL XG36
Part # 4517124 Rev. 7 (08/17/11)