Before plugging in the machine, make sure that the information on the nameplate (voltage, etc.)
matches that of the electrical.
Check the condition of the power supply cord; if it is damaged it must be replaced.
Completely unwind the power-supply cable.
Room temperature must range between 10° and 32°C (50°F and 90°F).
An electrical outlet must be in the immediate vicinity.
Do not install in rooms (kitchens) that are cleaned with jets of water.
Do not obstruct openings or ventilation and heat vents.
Do not install the machine outdoors.
Do not install or use the appliance in potentially explosive environments.
Prior to installation, make sure there is a circuit breaker installed with a distance between the contacts
that allows for complete disconnection when there is a category III overload and that provides
protection against current leakage equal to 30 mA. The circuit breaker must be installed on the power
supply in compliance with installation rules.
caused by the lack of an earthing system on the electrical supply.
Do not use adaptors, multiple plugs, and/or extension cords.
Check that the type of connection and voltage correspond with the information on the nameplate.
This type of connection, required by some laws, prevents differences in the electric potential level between the earthing
connections of equipment installed in the same room.
This machine is provided with a clamp underneath the base for connection to an external equipotential cable.
After installation, this type of connection MUST be made:
Use a cable with a nominal section in compliance with the laws in force.
Connect one end of the cable to the clamp and the other end to the earthing of adjacent equipment.
Failure to follow this safety norm releases the manufacturer from any responsibility for machine breakdowns or damage
to people or property.
NOTE: DO NOT CONNECT TO THE POWER SUPPLY EARTHING BECAUSE IT IS NOT CONSIDERED AN
EQUIPOTENTIAL CABLE CONNECTION.
Bear in mind that Gruppo Cimbali S.p.A. is not
responsible for damage caused by improper electrical
connections, and that the installer is responsible for
any damage.

2.2 Installation Rules

3. Electrical Installation Rules

4. Equipotential Connection

4 EN

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Cm od

Table des Matières