Before plugging in the machine, make sure that the information on the nameplate (voltage, etc.)
matches that of the electrical.
Check the condition of the power supply cord; if it is damaged it must be replaced.
Completely unwind the power-supply cable.
Room temperature must range between 10° and 32°C (50°F and 90°F).
An electrical outlet must be in the immediate vicinity.
Do not install in rooms (kitchens) that are cleaned with jets of water.
Do not obstruct openings or ventilation and heat vents.
Do not install the machine outdoors.
Prior to installation, make sure there is a circuit breaker installed with a distance between the contacts
that allows for complete disconnection when there is a category III overload and that provides
protection against current leakage equal to 30 mA. The circuit breaker must be installed on the power
supply in compliance with installation rules.
caused by the lack of an earthing system on the electrical supply.
Do not use adaptors, multiple plugs, and/or extension cords.
Check that the type of connection and voltage correspond with the information on the nameplate.

2.2 Installation Rules

3. Electrical Installation Rules