Fault
flashing red
LED info bar does not light up
Charging plug cannot be removed
from the charging station.
If you cannot rectify the error or fault, ask a qualified electrician to check the charging station.
Cause
Residual current circuit breaker (RCCB)
or circuit breaker (CB) in the charging
station has tripped.
Error in the power supply to the
charging station (incorrect phase
sequence, missing phase, etc.).
Charging plug not interlocked.
Incorrect or faulty charging cable.
Network error.
No power supply to the charging
station.
The back-up fuse of the charging
station has tripped.
Failure of the unlocking function.
Notes on troubleshooting
Re-activate residual current circuit
breaker (RCCB) or circuit breaker (CB).
 See Chapter 4.3.2 on page 11.
Ask a qualified electrician to check the
power supply of the charging station.
Disconnect charging cable and plug in
again.
Acknowledge the fault with multi-
function button.
Disconnect charging cable and plug in
again.
Check charging cable and replace if
necessary.
Acknowledge the fault with multi-
function button.
Check network or network settings.
Ask a qualified electrician to check the
charging station.
Check back-up fuse and re-activate if
necessary.
Ask a qualified electrician to check the
charging station.