Functional description of operating mode Energy Manager
Start of charging
process
Controlling the charging
process
15
Without RFID card:
 Automatically after connection to the vehicle
With RFID card:
 Authentication with valid RFID card
 Manually by selecting a valid RFID card in Charge APP.
By using the "SUNNY HOME MANAGER":
 The "SUNNY HOME MANAGER" specifies the charging current according to the parameters
set in the Charge APP.
 See Chapter 4.4.1 "Settings in operating mode "Energy Manager"" on page 17.
By using the Charge APP:
 Terminating the charging process (stop)
 Changing the remaining amount of charging energy.
 Changing the remaining charging time.
 Changing the distribution of solar energy (enable / disable excess charging).
By using the multi-function button:
 Terminating the charging process (stop)
The stop function with the multi-function button must be enabled during the setting-up
process.
With RFID card:
 Terminating the charging process (stop, with the same card used for starting the charging
process)
In operating mode "Energy Manager", all functions in operating modes "Time-
Controlled (internal)" and "External Tariff Signal" are suspended. The charging power,
for example, will not be controlled over the internal timer or external tariff-switching signal.