Publicité

Les langues disponibles
  • FR

Les langues disponibles

3. Setting of the operating parameters
a. Press both front side keys keys and switch on
the supply voltage or, if the supply voltage is
already on, press both keys simultaneously
during 5 s.
b. The display shows
c. After releasing the keys, the display shows
c1.Hold the left key pressed and press the right
key to leave the programming operation.
c2.Press the right key to switch to
.
d. Hold the left key pressed and press the right
key to switch to the first parameter.
e. After releasing the keys, the display alter-
nates between the menu title and the current
menu item setting. After pressing any key,
only the menu item setting is displayed.
f. Pressing the right key, the menu item setting
will be switched to the next value. If figures
are to be input (e.g. when setting the scaling
factor), select first the decade using the left
key, and then set the value using the right
key.
g. Hold the left key pressed and press the right
key to switch to the next menu item.
h. The last menu title "EndPro" allows, when se-
lecting "Yes", to exit the programming menu
and to take over (store) the new values. If
"no" is selected, the programming routine is
repeated, the latest values set remaining ac-
tive. They can now be checked again or mod-
ified.
4
4. Programming routine
The first menu item is the selection of the basic
operating mode, which determines the functions
of the device.
Operating mode pulse counter.
Continued in point 4. of CODIX
541 on page 4.
Operating mode frequency
meter. Continued in point 4. of
CODIX 542 on page 6.
Operating mode time meter.
Continued in point 4. of CODIX
543 on page 7.
Pulse counter/Position indicator
CODIX 541
(CODIX 544: Operating mode pulse counter)
1. Description
• 6-digit display counter with SET/RESET-func-
tion
• Red LED display, character height 14 mm
• Display range from -199 999 to 999 999
• Leading zeros suppression
• Programming via two setting keys on the front
side
• During programming, the display guides the
user with text prompts
• Counter operating modes:
Count input INP A + count direction input
INP B (Cnt.Dir)
Differential count INP A – INP B (up.dn)
Totalising INP A + INP B (up.up)
Count Up/Down INP A 90° INP B x 1 (quAd)
Count Up/Down INP A 90° INP B x 2 (quAd2)
Count Up/Down INP A 90° INP B x 4 (quAd4)
• With AC power supply: sensor supply
voltage 24 V DC ±15 %/100 mA
• Optional optocoupler output