Safety Technique
SAFEMASTER
Emergency Stop Module
BG 5924, IP 5924
BG 5924

Product Description

The emergency stop modules BG 5924 and IP 5924 can be used to protect
people and machines by interrupting a safety circuit in a safe way.

Function Diagram

Pushbutton
On
Emergency
stop (Off)
K1
K2

Block Diagrams

A1(+)A2(-)
Y1
overvoltage- and
short circuit protection
K1
24V
power
M7111_a
BG 5924.48, IP 5924.48
All technical data in this list relate to the state at the moment of edition. We reserve the right
for technical improvements and changes at any time.
IP 5924
M7218
Y2
13
23
33 41
monitoring
K1
logic
K2
K2
K1/K2
14
24
34 42
Your Advantages
• For safety application up to PL e / Cat. 4 e.g. SIL 3
• Manual or automatic start
Features
• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508
• According to EN 50156-1 for furnaces
• Single channel or two-channel operation
• Output: max. 4 NO contacts
• AC 230 V model with galvanic separation
• LED indicator for channel 1 / 2 and state of operation
• Short circuit detection between terminal Y1 and common
• BG 5924 with:
- Removable terminal strips
- Wire connection: also 2 x 1.5 mm
DIN 46 228-1/-2/-3/-4 or 2 x 2.5 mm
• BG 5924: width 22.5 mm
• IP 5924: width 70 mm

Approvals and Markings

* see variants
for BG 5924 only
1)

Applications

• Protection of people and machines
• Emergency stop circuits on machines

Indicators

LED Phase:
LED K1/K2:
A1(+)A2(-)
Y1
overvoltage- and
monitoring
short circuit protection
logic
K1
24V
power
M7112_a
BG 5924.02, BG 5924.02/110,
BG 5924.04, BG 5924.04/100,
IP 5924.02, IP 5924.04
13
stranded ferruled (isolated),
2
stranded ferruled DIN 46 228-1/-2/-3
2
*
*
Canada / USA
Canada
A025518
on, when supply connected
on, when relay K1 and K2 energized
.04
.02
Y2
13
23
33
43
K1
K2
K2
K1/K2
14
24
34
44
BG 5924 / 18.04.17 en / 849