4.5
Starting the generating set
If the outdoor temperature is above 0°C:
1.
Open the fuel taps (A6).
2.
Check that the air filter is in the normal position of use
(D1)
3.
If the generating set is cold, move the choke tab (A9) to
the "I" position.
4.
Turn the key (A8) to position B.
5.
Turn the key fully for a few seconds (position C).
If the unit does not start within 15 seconds, stop and wait 2
minutes before trying again (risking of damage).
If the unit does not start, use the starter-recoil to perform a
manual start.
4.5.1 Manually start the generating set
In the event of an electric starting fault, start the generating set manually:
1.
Turn the key (A8) to position (B).
2.
Slowly pull the starter/recoil reel handle (A10) until there is some resistance, then let it return slowly.
3.
Pull the starter-recoil reel handle hard, quickly then let it return to its initial position slowly.
If the unit does not start, wait one minute before repeating the process no more than three times.
4.6
Using the electricity supplied
1.
Allow the unit speed to stabilize and the temperature to rise (approx. 3 to 5 min.).
2.
If the choke was used, return it gradually to its original position.
3.
Connect the equipment to be used to the electrical sockets (A12) on the unit.
4.
Use the working hours counter (A11) to monitor the running time of the unit.
For France only: Our units are fitted with sockets where the earthing contact is made using side tabs.
In exceptional cases where the equipment is only fitted with an earthing pin, use an adaptor. After use,
always disconnect the adaptor and store it carefully, away from sources of moisture. Always ensure
that the socket cover on the unit is closed: risk of damage (loss of seal).
4.7
Switching the generating set off
1.
Disconnect the electrical sockets (A12) taking care to close the cover.
2.
Allow the unit to run idle for 1 or 2 minutes.
3.
Turn the key (A8): the unit will shut down.
4.
Close the fuel taps (A6).
5.
Ensure the unit is properly ventilated and to avoid any risk of fire, wait for it to be fully cool before covering it and storing it.
Even when the unit is turned off, the engine continues to give off heat.

5 Generating set maintenance

As a safety measure, maintenance should be performed on the generating set regularly and carefully by people who have the
necessary experience and are equipped with suitable tools, in respect of current regulations. The maintenance operations to be
carried out are detailed in the maintenance table. The interval for this is supplied as a guide and for generating sets operating with
fuel and oil which conform to the specifications given in this manual. The maintenance intervals can be shortened depending on the
generating set's operating conditions and requirements. It is important to note that the warranty shall not be valid if generating set
maintenance has not be performed correctly.
5.1
Reminder of use
Ensuring maintenance is performed regularly and correctly will guarantee safety and performance. The oil, filter elements and,
where present, the spark plug, are consumables which must be in good condition for the unit to operate correctly.
Replace them regularly as often as is needed (the reference for ready-to-use maintenance kits is given in the table of
technical specifications where applicable). The warranty becomes void in the event of failure to respect the maintenance
recommendations. For any questions about a special operation, please contact your nearest agent who will advise and help you.
5.2
Maintenance intervals table
The maintenance frequency is given as an indication only and is for devices using fuel and oil complying with the specifications
given in this manual. The maintenance intervals can be shortened depending on the unit's operating conditions and requirements.
Perform the maintenance operations at the indicated due dates even if the number of hours' operation has not been reached. The
warranty will be invalidated if maintenance of the unit has not been performed correctly.
Operation to be carried out:
Clean the unit
Unit
Clean the spark arrester
Replace the spark plug
Oil
Change
Replace the fuel filter
Fuel
Clean the sediment bowl
Clean
Air filter
Replace
Part numbers of parts to be used during maintenance:
If the outdoor temperature is below 0°C:
1. Open the fuel taps (A6).
2. Position the air filter in the "low temperatures" position (D2).
3. Move the choke tab (A9) to the "I" position.
4. Turn the key (A8) to position B.
5. Turn the key for a few seconds (position C).
If the unit does not start within 15 seconds, stop and wait 2 minutes before
trying again (risking of damage).
If the unit does not start, use the starter-recoil to perform a manual start.
After
Every
3 months/
5 hours
3 months/
50 hours
50 hours
X
X
X
X
X
19/222
Earthing pin. Use
the adaptor.
In hours, months or years, whichever comes first
Every
Every
6 months/
100 hours
X
X
Major service
X
to be carried
X
out by one of
our agents.
X
X
0.806.800.107
X
X
(call charge)
X
RKS2
Side tabs: OK.
Every
1 year/
2 years/
200 hours
500 hours
Major service
to be carried
out by one of
our agents.
France:
France:
0.806.800.107
(call charge)