7. Example of an individual scalable Display

By using the arrow buttons, the unit mode of the safety device can be
selected.
The programming unit works directly with the frequencies measured by the
safety unit. Which inputs are used by the safety unit, must be specified in the
"Operational Mode" of the safety unit.
*) If the version of the safety device is lower than 04A, scaling parameters are
in SMCB-Display. When safety device version is higher than 04A, scaling
parameters are in the "OPU Menu" of the safety device.
Changes will be only effective after saving! See chapter 0
The calculation of an individual scalable display is built-up as follows:
The unit („Units") as well as the number of decimal places are freely
selectable and have no influence to the accuracy of the calculation.
Examples for an input frequency of 1 kHz:
If 1000.0 [Hz] is shown in display 1 „Frequency", the parameter group „Input
Scaling" can be used to adjust the following scaling's, which are then
indicated in display 3.
Display 1:
„Frequency
"
1000.0 [Hz]
1000.0 [Hz]
1000.0 [Hz]
1000.0 [Hz]
1000.0 [Hz]
*) Number of pulses per encoder revolution
Parameters of the group „Input Scaling" see chapter 6.1
Display 1 „Frequency" resp. display 3/4 „Scaled Input" see chapter 5.1
Doc. # R60718
X
Divisor
Factor
1
10
1
1
1
1000
1
1
60
2048*
Example of an individual scalable Display
+/-
Units
Value
0
12
0
0
0
1
0
1
0
6
Display 3/4
Decima
„Scaled
l Point
Input"
0
1000
1
1000.0 [Hz]
1
1.0 [kHz]
4
1.0000 [kHz]
2
29.29 [rpm]
EN - 27