Technical Data; General Data/Operating Conditions - Lenze ECSCK Serie Instructions De Montage

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2

Technical data

2.1

General data/operating conditions

Standards and operating conditions
Conformity
Approvals
Vibration resistance
Climatic conditions
Degree of pollution
Packaging (DIN 4180)
Permissible
Transport
temperature range
Storage
Operation
Permissible installation height
Installation
Mounting position
Free space
Above
Below
To the sides
EDKCSCK002 DE/EN/FR 1.1
General data/operating conditions
CE
Low−Voltage Directive (73/23/EWG)
UL 508C
Power Conversion Equipment
Underwriter Laboratories (file no. E132659)
for USA and Canada
Accelerational stability up to 0.7 g (Germanischer Lloyd, general
conditions)
Class 3K3 to EN 50178 (without condensation, relative humidity
30 ... 95 %)
VDE 0110 part 2 pollution degree 2
Delivery packing
−25 ... +70 °C
−25 ... +55 °C
0 ... +55 °C
reduce the rated AC current by 2 %/°C above +40°C
0 ... 4000 m amsl
reduce rated AC current by 5%/1000 m above 1000 m
amsl
Installation into control cabinet
Vertically suspended
³ 65 mm
³ 65 mm
with shield assembly set ECSZS000B0B001: > 195 mm
Side−by−side mounting without any clearance
l