How To Hang Your Ceiling Fan - Emerson LINDELL CF825AP00 Mode D'emploi

Ventilateur de plafond de 52 po
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

WARNING
!
The fan must be hung with at least 7' of clearance from
floor to blades (Figure 13).
WARNING
!
Turning off wall switch is not sufficient. To avoid possible
electrical shock, be sure electricity is turned off at the
main fuse box before wiring. All wiring must be in
accordance with National and Local codes and the ceiling
fan must be properly grounded as a precaution against
possible electrical shock.
WARNING
!
The outlet box and joist must be securely mounted and
capable of supporting at least 50 lbs. Use only a
U.L. outlet box listed as "Acceptable for Fan Support of
22.7 kg. (50 lbs.) or less".
WARNING
!
To reduce the risk of fire, electric shock, or personal
injury, mount fan to outlet box marked "Acceptable for
Fan Support of 22.7 kg. (50 lbs.) or less", and use screws
supplied with outlet box. Most outlet boxes commonly
used for support of light fixtures are not acceptable for
fan support and may need to be replaced. Consult a
qualified electrician if in doubt.
4.1
Securely attach the Hanger Bracket to the Outlet Box
using the two Screws supplied with the Outlet Box
(Figure 14).
WARNING
!
Hanger bracket must seat firmly against outlet box. If the
outlet box is recessed, remove wall board until bracket
contacts box. If bracket and/or outlet box are not securely
attached, the fan could wobble or fall.

4. How to Hang Your Ceiling Fan

AT LEAST
7'
Figure 13
OUTLET BOX
HANGER BRACKET
TWO SCREWS
SUPPLIED WITH
OUTLET BOX
Figure 14
11
CEILING
FLOOR
ANTI-ROTATION
TAB
emersonfans.com
Please contact 1-800-654-3545 for further assistance
U.L. Model No.: CF825

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Lindell cf825orb00Lindell cf825bs00Lindell cf825sw00

Table des Matières