Refer to the
Quick Start Guide
Refer to the
Testing Guide
the accuracy of low range turbidity measurements.

GENERAL INFORMATION

 PACKAGING AND DELIVERY
Experienced packaging personnel at LaMotte Company assure adequate protection
against normal hazards encountered in transportation of shipments.
After the product leaves LaMotte Company, all responsibility for safe delivery is assured
by the transportation company. Damage claims must be fi led immediately with the
transportation company to receive compensation for damaged goods.
 GENERAL PRECAUTIONS
READ THE INSTRUCTION MANUAL BEFORE ATTEMPTING TO SET UP OR OPERATE THE METER.
Failure to do so could result in personal injury or damage to the meter. The meter should
not be used or stored in a wet or corrosive environment. Care should be taken to prevent
water from wet tubes from entering the meter chamber.
NEVER PUT WET TUBES IN THE METER.
 SAFETY PRECAUTIONS
*WARNING: Reagents marked with an * are considered to be potential health hazards. To
view or print a Safety Data Sheet (SDS) for these reagents go to www.lamotte.com.
Search for the four digit reagent code number listed on the reagent label, in the contents
list or in the test procedures. Omit any letter that follows or precedes the four digit code
number.
For example, if the code is 4450WT-H, search 4450. To obtain a printed copy, contact
LaMotte by email, phone or fax.
Emergency information for all LaMotte reagents is available from Chem-Tel: (US, 1-800-
255-3924) (International, call collect, 813-248-0585).
Ensure that the protection provided by this equipment is not impaired. Do not install or use
this equipment in a manner that is not indicated in this manual.
 LIMITS OF LIABILITY
Under no circumstances shall LaMotte Company be liable for loss of life, property, profi ts,
or other damages incurred through the use or misuse of their products.
 SPECIFICATIONS - 2020t/i
Mode
Unit of Measure
2020t
Unit of Measure
2020i
Range
for simplifi ed Calibration and Analysis procedures.
for detailed Calibration and Analysis procedures for improving
Nephelometric
NTU, ASBC, EBC
NTU, FNU, ASBC, EBC
0-100 NTU/FNU
0-1,750 ASBC
0-25 EBC
Ratiometric
NTU, NTRU, ASBC, EBC
NTU, FNRU, ASBC, EBC
0-1,000 NTRU/FNRU
0-17,500 ASBC
0-250 EBC
4
Attenuation
NTU, AU, ASBC, EBC
NTU, FAU, ASBC,
EBC
0-2,000 AU/FAU
0-70,000 ASBC
0-1,000 EBC