INDOOR EXHAUSTING
NOTE: MOBILE HOME, BEDROOM, BATHROOM, ALCOVE
OR CLOSET INSTALLATIONS MUST BE EXHAUSTED TO
THE OUTDOORS
OTHER INSTALLATIONS: If the installation makes it
impossible to exhaust to the outdoors, a 4" exhaust
deflector (WE25X278) must be installed. A clearance of 8"
is required between the rear of the dryer and the wall, and
the deflector should be pointing up.
NOTE: EXHAUSTING TO THE OUTDOORS IS STRONGLY
RECOMMENDED, EXHAUSTING INDOORS MAY CAUSE
LINT ACCUMULATION, AND MOISTURE DAMAGE
INCLUDING MOLD AND MILDEW.
ALCOVE OR CLOSET INSTALLATION
6
• If your dryer is approved for installation in an alcove or
closet, it will be stated on a label on the dryer back.
• The dryer MUST be vented to the outdoors. See the
EXHAUST INFORMATION sections 3 & 4.
• Minimum clearance between dryer cabinet and adjacent
walls or other surfaces is:
0 in. either side
3 in. front and rear
• Minimum vertical space from floor to overhead cabinets,
ceiling, etc. is 52 in.
• Closet doors must be louvered or otherwise ventilated
and must contain a minimum of 60 sq. in. of open area
equally distributed. If the closet contains both a washer
and a dryer, doors must contain a minimum of 120 sq. in.
of open area equally distributed.
BATHROOM OR BEDROOM
7
INSTALLATION
• The dryer MUST be vented to the outdoors. See
EXHAUST INFORMATION section 3 & 4.
• The installation must conform with local codes or, in the
absence of local codes, with the NATIONAL ELECTRICAL
CODE, ANSI/NFPA NO. 70.
MOBILE OR MANUFACTURED
8
HOME INSTALLATION
• Installation must conform to the MANUFACTURED HOME
CONSTRUCTION & SAFETY STANDARD, TITLE 24, PART
32-80 or, when such standard is not applicable, with
AMERICAN NATIONAL STANDARD FOR MOBILE HOME,
ANSI/NFPA NO. 501B.
• The dryer MUST be vented to the outdoors with the
termination securely fastened to the mobile home
structure. (See EXHAUST INFORMATION section 3 & 4.)
• The vent MUST NOT be terminated beneath a mobile or
manufactured home.
• The vent duct material MUST BE METAL.
• Do not use sheet metal screws or other fastening devices
which extend into the interior of the exhaust vent.
• See section 2 for electrical connection information.
DRYER EXHAUST TO RIGHT, LEFT
9
OR BOTTOM CABINET
WARNING - BEFORE PERFORMING
THIS EXHAUST INSTALLATION, BE SURE TO
DISCONNECT THE DRYER FROM ITS
ELECTRICAL SUPPLY. PROTECT YOUR
HANDS AND ARMS FROM SHARP EDGES
WHEN WORKING INSIDE THE CABINET. BE
SURE TO WEAR GLOVES.
REMOVE
SCREW
AND SAVE.
Detach and remove the bottom, right or left side knockouts
as desired. Remove the screw inside the dryer exhaust
duct and save. Pull the duct out of the dryer.
B
Cut the duct as shown and keep portion A.
TAB LOCATION
BEND TAB
UP 45
o
Through the rear opening, locate the tab in the middle of
the appliance base. Lift the tab to about 45º using a flat
blade screwdriver.
9
REMOVE
DESIRED
KNOCKOUT
(ONE ONLY).
FIXING HOLE
A
9"

Publicité