Commissioning
Code
No.
Name
2
c20
I
t switch-off (thermal
motor monitoring)
Motor Overload Type
c21
c40
Frequency setpoint via
keys
c42
Start condition
(with mains on)
c43
Flying restart selection
Motor auto-
c48
calibration
c60
Mode selection for c61
18
Possible Settings
Lenze Selection
100
30
{%}
100% = Tml rated output current
WARNING!
Maximum setting is rated motor current (see nameplate). Does not provide full motor
protection!
00
00 Speed Compensation
Reduces the allowable continuous current
when operating below 30Hz.
01 No Speed Compensation
Example: Motor is cooled by forced
ventilation as apposed to shaft mounted,
self cooling fans.
0.0
0.0
{Hz}
1
0
Start after LOW-HIGH change at
terminal 28
1
Auto start if terminal 28 = HIGH
2
Flying restart (auto start disabled)
3
Auto start if terminal 28 = HIGH,
with flying restart
WARNING!
Automatic starting/restarting may cause damage to equipment and/or injury to
personnel! Automatic starting/restarting should only be used on equipment that is
inaccessible to personnel.
0
0
Search range: C11...0 Hz
1
Search range: last frequency...0 Hz
0
0
Calibration not done
1
Calibration enabled
2
Calibration complete
0
0
Monitoring only
1
Monitoring and editing
Lenze 13466187 EDBTL03 v8 EN, DE, FR, IT, ES
IMPORTANT
100
0C6
• Triggers
fault when motor
current exceeds c20 for too long
• Correct setting = (motor
nameplate current) / (Tml
output current rating) X 100%
Example: motor = 6.4 amps
and Tml = 7.0 amps;
correct setting = 91%
(6.4 / 7.0 = 0.91 x 100% = 91%)
1
Ir
100%
0
60%
30
Ir: rated current (%), f: motor frequency
(Hz)
240
Only active if C01 is set properly
(C01 = 1, 3, 5,7)
See also c43 and c70
If c42 = 2 or 3, the controller will start
the motor speed search at C11, or at
the last output frequency before the
fault, depending on the setting of c43
• If C14 = 4...7, motor calibration
must be performed, but C86...
C91 must be programmed first
(see C14)
• If motor calibration is attempted
before programming C86...C91,
triggers n1d fault
c60 = 1 allows the keys
adjust speed setpoint (c40) while
monitoring c61
f