Tools and Parts

Gather the required tools and parts before starting installation.
Tools needed
Level
I
Utility knife
I
Scissors
I
200 mm (8") or 250 mm
I
(10") adjustable wrench
Parts supplied
Remove parts bag from washer. Check that all parts were
included.
1 Hose clamp
I
2 Inlet hoses
I
4 Flat water hose washers
I
Technical
Specifications:
220 – 240 V, 50 Hz. AC
650 Watts

Location Requirements

IMPORTANT: Do not install or store the washer where it will be
exposed to the weather. Do not store or operate the washer in
temperatures at or below 0°C (32°F). Some water can remain in
the washer and can cause damage in low temperatures.
Proper installation is your responsibility.
You will need:
A water heater set to deliver 60°C (140°F) water to the washer.
I
An earthed electrical outlet located within 1.2 m (4 ft) of where
I
the power cord is attached to the back of the washer.
See "Electrical Requirements."
Hot and cold water taps located within 1.2 m (4 ft) of the back
I
of the washer, and provide water pressure of 69-690 kPa (10-
100 psi). A pressure reduction valve should be used in the
supply line where inlet pressure entering the building
exceeds 690 kPa (100 psi) to prevent damage to the washer
mixing valve.
A level floor with a maximum slope of 25 mm (1") under entire
I
washer.
A sturdy floor to support the washer weight (washer, water,
I
and load) of 143 kgs (315 lbs).
4

INSTALLATION REQUIREMENTS

Flat-blade screwdriver
I
Pliers
I
Bucket
I
2 Front-leveling legs
I
with nuts
1 Drain hose
I
Hose adapter
I
Clothes
Capacity:
MAT14CS: 5.9 Kg Max.
MAT15MN: 8.2 Kg Max.
Recessed Area and Closet Installation Instructions
This washer may be installed in a recessed area or closet.
The installation spacing is in inches and is the minimum
allowable. Additional spacing should be considered for ease
of installation, servicing, and compliance with local codes and
ordinances.
If closet door is installed, the minimum unobstructed air openings
in the top and bottom are required. Louvered doors with
equivalent air openings are acceptable.
432 mm
(17")
1.55 m
(24 in
0 mm
0 mm
(0")
(0")
Recessed front view
3.10 m
2
(48 in
2
)*
Front view
1.55 m
2
(24 in
2
)*
*Opening is the minimum for a closet door.
Louvered doors with equivalent air openings are acceptable.
I Additional spacing should be considered for the ease of
installation and servicing.
I Additional clearances may be required for wall, door, and floor
mouldings.
I Additional spacing of 25 mm (1") on all sides of the washer is
recommended to reduce noise transfer.
I Companion spacing should also be considered.
Closet door
3.10 m
2
(48 in
2
)*
2
2
)*
25 mm (1")
min.
Closet side view
76 mm (3")
closet
door
76 mm (3")
356 mm
(14") max.
102 mm
(4") min.