1.3 Control Functions

Button
Action
Short press: If the terminal is Off, power on the terminal; if the terminal is On, clear
the data input.
Long press: Power off the terminal.
Short press: Send the current display value to RS232 port or Option when properly
enabled.
Long press: Change the current weighing unit. Press and hold the key to scroll through
the list of enabled units. Release the key to switch to the unit selected.
Short press: Press the key to enter the Library.
Long press: Press and hold this key to change weighing modes. Press and hold the
key to scroll through all weighing modes. Release the key to switch to the mode
selected.
Short press: Press the key to enter user profile.
Long press: Press the key to enter user menu.
The 5 Softkeys correspond to several icons at the bottom of the display area. These
icons indicate for each Softkey functions specifically available for configuration and
operation of the mode.
To enter '2'-'9', press the numeric button in the mode of numeric input.
To Enter 'A', press
enter 'z', press
To enter '0', press the button in the mode of numeric input. To enter a
space, press the button in the mode of uppercase or lower case input.
To enter '1', press the button in the mode of numeric input. To enter
'#' or '/', press the button in the mode of uppercase input. To enter '@',
'_' , '&', '!' or '?', press the button in the mode of lowercase input.
Switch between three input modes ‒ numeric, lowercase and
uppercase input.
To enter '.', press the button in the mode of numeric input. To enter
'+' or '-', press the button in the mode of uppercase or lowercase
input.
Short press: When the load on the pan is within the zero range, press this key to set
the display to zero.
Short press: When a container is on the pan, press this key to store the weight of the
container as the tare value.
Short press: Enter the known weight of a container using the numeric keypad, and
then press this key to establish the preset tare value.
Short press: When a tare has been entered, empty the pan and press this key to
clear the tare value.
Long press: If a preset tare has been entered, press this key to view the preset tare
value.
2 times in the mode of uppercase input. To
5 times in the mode of lowercase input.
EN-9