Frost Protection; Faults - Kärcher B 80 W Bp Mode D'emploi

Masquer les pouces Voir aussi pour B 80 W Bp:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

 Connect the connection cable to the
free battery poles (+) and (-).
Note: The red connecting cable has an
increased protective layer. In order for
the tank not to touch when close, the
connecting cable must be connected as
shown in the illustration.
 Tilt the wastewater tank down.
Warning
Charge the battery before using the ma-
chine.
DANGER
Risk of injury! Before working on the appli-
ance, remove the Intelligent Key and the
mains plug of the charger.
 Drain and dispose of the dirty water and
the residual fresh water.
Display
ERR_I_BÜRSTE_049
ERR_I_TURB_050
ERR_U_BATT_001
If the display shows different error messag-
es or if the error cannot be remediated:
 Remove the Intelligent Key.
 Wait for 10 seconds.
 Plug in the Intelligent Key.
 If the fault recurs, call customer service.
Fault
Remedy
Machine does not
Stand-by. Turn the appliance off and reinsert the Intelligent Key.
move
Turn the program selection switch to the desired programme.
Release parking brake.
Check battery; charge it if required.
Make sure that all battery terminals are connected.
Insufficient water quan-
Check fresh water level, refill tank if necessary.
tity
Increase the water volume on the regulating knob for water volume.
Unscrew the lock of the fresh water reservoir. Remove and clean the fresh water filter. Insert the filter and
screw in the lock.
Remove the water distribution strip from the cleaning head and clean water canal (only R cleaning head).
Check hoses for blockages; clean if required.
Do not add detergents Increase the water volume to activate the dosing pump.
Check the detergent level
Removing the batteries
CAUTION
‫ ‏‬R isk of damage due to tipping appliance;
remove batteries only if the appliance is
equipped with a cleaning head.
 Remove the Intelligent Key.
 Push the appliance forward about 2 m
so that the steering rollers point toward
the rear.
 Hold the wastewater reservoir by the
handle recess and swivel the reservoir
upwards toward the side.
 Remove the connection for the minus
pole of the battery.
 Remove the remaining connector from
the battery
 Remove the support blocks.
 Remove the batteries.
Remedy
Check if foreign matters block the brushes; remove foreign matter if required.
Check suction turbine for contamination and clean it if necessary.
Check battery; charge it if required.
Faults without display on the console

Faults

Faults with display
11
-
US
CAUTION
When the batteries are installed and re-
moved, the stability of the appliance can be
compromised; ensure a safe stance.
 Dispose of the used batteries according
to the local provisions.
Maintenance contract
To ensure a reliable operation of the appli-
ance maintenance contracts can be con-
cluded with the competent Kärcher sales
office.

Frost protection

In case of danger of frost:
 Empty the solution and recovery tank .
 Store the appliance in a frost-protected
room.
13

Publicité

Table des Matières
loading