SOLUTION/CLEAN WATER FILTER CLEANING

1.
Drive the machine on a level floor.
2.
Press the switch (71) and/or (73) to turn the machine off.
3.
Close the solution tap (A, Fig. 5) under the machine, behind the right rear wheel. The tap (A) is closed when it is on the
position (B) and it is open when it is on the position (C).
4.
Remove the transparent cover (D), then remove the filter strainer (E). Clean and install them on the support (F).
NOTE
The filter strainer (E) must be correctly positioned on the housing (G) of the support (F).
5.
Open the tap (A).
G
E

FUSE CHECK/REPLACEMENT

1.
Disconnect the battery connector (12).
2.
Move aside the recovery water drain hose (16).
3.
Remove the battery charger cable (I, Fig. 6) from the holder (J).
4.
Remove the screws (A) and carefully move aside the panel (B) by disengaging the grommet (K) from its housing on the
panel (B).
5.
Check/replace the following fuses:
(C) F1 fuse, deck: (40 A)
(D) F2 fuse, vacuum system: (30 A)
(E) F4 fuse, signal circuits: (3 A)
6.
Perform steps 1 to 4 in the reverse order.
9096912000(1)2006-09
F
E
D
A
F
A
J
I
INSTRUCTIONS FOR USE
Figure 5
A
B
D
A
K
Figure 6
A
B
C
C
S311338