Pump does not
operate and icon
does
Pump Priming Instructions:
This method must be used for the jets pumps because these pumps
are not connected to the main filter system in any way.
1. Turn off the power to the spa.
2. Remove the handle from the massage selector supplied by the pump
you are priming.
3. Loosen the massage selector's cap slightly (counterclockwise),
listening for the air to seep out.
4. Tighten the cap finger tight, replace the handle, and turn the spa's
power back on.
CAUTION: If freezing conditions exist and pump is not operational,
take measures to protect the system from freeze damage. See Section
titled "Winterizing," page 66.
PROBLEM
Poor jet
action
(Sections
9.4-9.25,
pages
24-45)
Water is too
hot
No heat
Depress JETS Button.
1.
If no sound is detected or if a buzzing sound
is detected, turn off power to the spa and
contact your authorized dealer or qualified
service technician.
2.
If motor operates, but now water flows to
jets:
A. Pump may not be properly primed. See
instructions below.
B. Contact your Sundance Spas dealer or
qualified service technician.
PROCEDURE
1.
Make certain the jets pump is turned on.
2.
Check position of massage selectors.
3.
Open air control for selected jet system.
4.
Check for adequate water level.
5.
Check for dirty filter (pages 60-62).
1.
Reduce thermostat setting (page 18).
2.
Switch hot tub to "Economy" mode to turn heater on
only during programmed filter cycles (page 54).
1. Check thermostat setting.
2. Keep the cover in place while heating.
3. If "heater on" indicator is lit but no temperature rise
is experienced after a reasonable period of time,
contact your Sundance Spas dealer or qualified
service technician.