2.2 Energy Management System (EMS)

The EMS incorporates a hygrometer that monitors the pressure dewpoint of the air at the outlet of the dryer. At the point in the cycle when the
regenerating bed has been pressurised (180 seconds) both beds will be at line pressure and no purge air will be consumed. If the air at the outlet
is drier than the pre-set dewpoint, regeneration is not required and changeover is delayed. The ECO indicator on the front panel will illuminate at
this point to show that the dryer is in energy saving mode.
Changeover will occur after 1800 seconds or when the pressure dewpoint of the air at the outlet of the dryer rises above the upper pre-set
dewpoint.
Dewpoint Setting
Lower Pre-set Dewpoint
Upper Pre-set Dewpoint
Side A
Side B
Drying

2.3 Technical Specification

Flow Data
Dryer Model
MXLE 102C
MXLE 103C
MXLE 103
MXLE 104
MXLE 105
MXLE 106
MXLE 107
MXLE 108
Stated flows are for operation at 7 bar g (100 psi g / 0.7 MPa g) with reference to 20ºC, 1 bar a, 0% relative water vapour pressure.
Performance
Dryer Model
MXLE
1 ISO 8573-1 classifications apply when the dryer is installed with the filtration supplied
Operating Data
Dryer Model
MXLE 102C - 108
-40 PDP
o
C
-46
-43
Depressurisation
Pipe Size
G 2
G 2
G 2
G 2
G 21/2
G 21/2
G 21/2
G 21/2
Pressure
ISO 8573-1:2010
Dewpoint
Water Classification
(Standard)
o
o
(Standard)
C
F
-40
-40
Class 2
Min Operating
Max Operating
Pressure
bar g
psi g
bar g
5
72.5
13
-20 PDP
o
o
F
-50.8
-26
-45.4
-23
EMS Drying and Regeneration Cycle
Time (Seconds)
Regeneration
3
L/s
m
/min
113
170
10.22
213
12.78
283
17.03
354
425
496
567
Pressure
Dewpoint
Water Classification
(Optional)
o
o
C
F
1
-70
-100
Min Operating
Pressure
Temperature
o
psi g
C
190
5
o
C
F
-48.8
-9.4
Repressurisation
3
m
/hr
6.81
408
612
765
1020
21
1275
26
1530
30
1785
34
2040
Pressure
ISO 8573-1:2010
Dewpoint
(Optional)
o
(Optional)
C
*
-20
Class 1
Max Operating
Temperature
o
o
F
C
41
50
122
-70 PDP
o
o
C
F
-76
-104.8
-73
-99.4
Energy Saving (EMS)
cfm
240
360
450
600
750
900
1050
1200
ISO 8573-1:2010
Water Classification
o
(Optional)
F
*
-4
Class 3
Max Ambient
Temperature
o
o
o
F
C
F
55
131
5