2.7.1 Storage

The equipment should be stored, within the packing crate, in a clean dry environment. If the crate is stored in an area where the environmental
conditions fall outside of those specified in the technical specification, it should be moved to its final location (installation site) and left to stabilise
prior to unpacking. Failure to do this could cause condensing humidity and potential failure of the equipment.

2.7.2 Unpacking

Remove the lid and all four sides of the packing crate (A) and unscrew the exhaust silencer from the dryer (B). Lift the dryer on to its feet using
suitable slings and an overhead crane (C, D and E).
Carefully move the dryer to its final location, using a forklift truck or pallet truck, and refit the silencer (F).
A
D

2.7.3 Vacuum Pump

The vacuum pump is supplied separately from the dryer. Check that the pump supplied corresponds to the pumps referenced below:-
Dryer
Vacuum Pump Kit
MXLE 102C
MXLEP2C-E
MXLE 103C
MXLEP3C-E
MXLE 103
MXLEP3-E
MXLE 104
MXLEP4-E
MXLE 105
MXLEP5-E
MXLE 106
MXLEP6-E
MXLE 107
MXLEP7-E
MXLE 108
MXLEP8-E
MXLE 102C
MXLEP2C-E-60
MXLE 103C
MXLEP3C-E-60
MXLE 103
MXLEP3-E-60
MXLE 104
MXLEP4-E-60
MXLE 105
MXLEP5-E-60
MXLE 106
MXLEP6-E-60
MXLE 107
MXLEP7-E-60
MXLE 108
MXLEP8-E-60
10
B
E
Vac Pump Kit Contains
Vac Pump 1
VC150
VC150
VC202
VC303
VC303
VC202
VC303
VC303
VC150
VC150
VC202
VC303
VC303
VC202
VC303
VC303
C
F
Vac Pump 2
-
-
-
-
-
VC202
VC202
VC202
-
-
-
-
-
VC202
VC202
VC202

Publicité

Table des Matières
loading

Table des Matières