The motor protection units are factory set for use with an electrical supply frequency of 50hz. The default settings can been seen in the below
table.
50hz MPU set points:
Dryer Model
MXLE102C
single - V-VC 150
MXLE103C
single - V-VC 150
MXLE103
single - V-VC 202
MXLE104
single - V-VC 303
MXLE105
single - V-VC 303
MXLE106
duplex - V-VC 202 2 x 2 off
MXLE107
duplex - V-VC 303 & V-VC 202
MXLE108
duplex - V-VC 303 & V-VC 202
If the dryer electrical supply frequency is 60hz then adjust the relevant motor protection units to the required set points below
60hz MPU set points:
Dryer Model
MXLE102C
single - V-VC 150
MXLE103C
single - V-VC 150
MXLE103
single - V-VC 202
MXLE104
single - V-VC 303
MXLE105
single - V-VC 303
MXLE106
duplex - V-VC 202 2 x 2 off
MXLE107
duplex - V-VC 303 & V-VC 202
MXLE108
duplex - V-VC 303 & V-VC 202
Note - If running 60hz frequency you must have a minimum voltage supply of 460v ac 3phs to run the dryer & pump.
3.1 First Time Start Up
Ensure that the isolation valves on the inlet and the outlet of the dryer are closed.
1
Turn the dryer ON at the isolator and verify that the display illuminates.
2
Slowly open the isolation valve on the inlet of the dryer and verify that there are no leaks.
3
Check that the upper pressure gauge (PRV1) is reading 7 barg and adjust if required.
4
Do not adjust the regulators away from 7 barg.
Check that the system pressure relief valve is closed.
5
Test the condensate drains of the filters and ensure they are discharging correctly into a suitable collection vessel.
6
Press and release the start control then immediately turn the dryer off at the isolator.
7
Check that the pump is rotating in the direction marked on the pump (clockwise). If the pump is rotating in the wrong direction, isolate the
8
electrical supply and swap two phases over on the vacuum pump supply cable terminals.
20
Pump Models
Pump Models
MPU1
MPU2
9
N/A
9
N/A
10
N/A
13
N/A
13
N/A
10
10
13
10
13
10
MPU1
MPU2
9
N/A
9
N/A
13
N/A
17
N/A
17
N/A
13
13
17
13
17
13