Troubleshooting Chart

Symptom
N
Motor will not start
G
L
I
S
H
Starter trips repeatedly
Tank pressure builds up slowly
Tank pressure builds up quickly
ASME pressure relief valve pops
off while compressor is running
Excessive belt wear
For Service and Warranty, Call: 1-888-303-1344.
®
10 & 15 HP
Always disconnect unit from power supply and relieve all pressure from air tank before
Possible Cause(s)
1. Main switch and fuses open
2. Starter heater coils open
3. Starter tripped
4. Defective pressure switch-
contacts will not close
5. Low voltage
1. Improperly adjusted pressure
switch
2. Faulty check valve
3. Incorrect fuse size or magnetic
starter heaters
4. Low voltage
5. Defective moto
1. Air leaks
2. Dirty air filter
3. Defective compressor valves
Excessive water in tank
1. Wrong pressure switch setting
2. Defective ASME relief valve
1. Pulling out of alignment
2. Belts too tight or too loose
1. Check all fuses and switches. Check
for loose or faulty wires
2. Check overload relay in starter
Reset starter
3. Reset starter. If starter trips
repeatedly, have electrical system
inspected by an electrician
4. Repair or replace pressure switch
Warning – Relieve tank pressure
before servicing
5. Check with voltmeter Be sure
voltage corresponds to unit
specifications
1. Adjust or replace
Warning – Relieve tank pressure
before servicing
2. Clean or replace
Warning – Relieve tank pressure
before servicing
3. Be sure that fuses and heaters are
roperly rated
4. Check with voltmeter. Be sure
voltage corresponds to unit
specifications
5. Replace motor
1. Tighten fittings
2. Clean or replace
3. Install new valve plate assembly
Drain tank
1. Adjust to correct setting
2. Replace valve
Warning – Relieve tank pressure
before servicing
1. Realign motor pulley
2. Adjust belt tension