Remove the horizontal auger; this way the inox side of the tank is completely open and ready to
be cleaned (pic. 18 and 19 in appendix-88).
Remove the outlet (pic. 20, 21, 22, 23 in appendix-88) and the tank gasket (pic. 24 in appendix-
88):
Remove the lever cover (pic. 20 in appendix-88) by pushing "PUSH" downward; and remove
the lever (pic. 21 in appendix-88);
Rotate the ring nut clockwise (pic. 22 e 23 in appendix-88) and pull the outlet.
Dip the dismantled parts in the solution of water and bleach.
Wash and dry.
Wet the gasket before inserting it in place (pic. 24 in appendix-88), be careful to place the gasket
joint in one of the back corners of the tank in the proper allocation.
Reassemble everything.
When you put the tank back in its place verify that the low tension contact wires are in the guides
of the terminal board. If they are not, the lamp and the augers will not work (pic. 25 in appendix-
88).
Connect the machine to the power supply.
Warning! Any time the covers (lamp) are removed, for security reasons, the augers and
the cooling system will stop working.
Remove the side panel of the 2 or 3 tanks machine, or the back panel of the one tank machine by
unscrewing the screws on the bottom and clean the radiator with a soft brush or (if possible) with
compressed air.
First Class has an accessory called Restriction (pic. 28 in appendix-88), it is a shaped piece that is
applied on the ending part of the transparent tank outlet. It has the following advantages:
The product, liquid (clod drink) or semi-liquid (low density slush), is canalized directly in the glass;
The restriction is easy to pull out, therefore, it is possible to easy wash the ending part of the
outlet without having to dismantle the whole transparent tank, with a consequent decrease of the
machine cleaning times. In summary, the only part which is not refrigerated, where an
accumulation of the product is more likely to happen, can be now removed and washed.
This restriction has some gaskets (O-ring) that must be wet with water before inserting
them on the outlet terminal part. This is to make the introduction easier and to avoid that
O-ring goes outside their proper locations.
On the restriction there is the image of an arrow and of a glass that, while inserting it,
must face the operator.
Condenser cleaning procedure
Outlet restriction
- 21 -