- Troubleshooting
Fault
1- The vacuum suddenly stops
2- Dust leaks from the vacuum
3- The vacuum blows instead of
sucking
4- Electrostatic current on the
vacuum
Causes
1- Clogged main filter
1- Clogged suction hose
1- Motor protector tripper
2- The filter is torn
2- Inadequate filter
3- Incorrect connection to the
electricity main
4- Non existent or inefficient
earthing
49-
Tutti i diritti riservati / All rights reserved
Tous droits réservés / Alle Rechte vorbehalten
Remedies
1- Shake the filter. Replace it
if this is not sufficient
1- Check the suction hose and
clean it
1- Check the setting.
Check the power draw of
the motor. Contact an au-
thorized after-sales service
centre if necessary
2- Change it with another of
identical category
2- Change it with another of a
suitable category and check
3- Remove the plug and in-vert
two of the live wires
4- Check all earth connec-
tions. Particularly check the
suction inlet
Lastly, the hose must be
strictly antistatic