Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

CV Name
8
Manufacturer ID
17
Long address
18 Long address
GB
28 RailCom
1)
29 Con�guration register Diverse locomotive settings, only relevant in DCC

30 Error information

14
8010885920 XII_2012.indd 14
Description
Read:NMRA manufacturer identification number.
ROCO has 161
Write: By programming this CV, individual CVs can be
reset to factory default. Example: CV8 = 3 replaces the
CV3 to its factory default.
High-value byte
Low-value byte
Selecting the RailCom
1)
transmission functions
Bit
Function
0
Broadcast off
Broadcast on
1
Transmitting the CV data off
Transmitting the CV data on
operation. Add the values of each of the functions to
determine the value of the CV29
Bsp.: 28 driving stages + permit analogue
operation = 2+4 = 6.
Bit Function
0 Normal direction of travel
Direction reversal
1
14 driving stages in DCC system
28 / 128 driving stages in DCC system
2
Deactivate analogue operation Activate
analogue operation
3
RailCom
1)
off
RailCom
1)
on
4 3-point characteristic line in
accordance with CV2, CV5, CV6
28-point characteristic line in
accordance with CV67 -CV94
5
Use short address (CV1) in DCC
operation
Long address (CV17+18) in DCC ope-
ration
As soon as an error occurs it will be stored in CV30.
By writing a random value,
the CV30 can be deleted again.
Bit 0 = 1: short-circuit L1 detected
Bit 1 = 1: short-circuit L2 detected
Bit 6 = 1: short-circuit motor detected
Bit 7 = 1: Overtemperature detected
Value
Works
Range
Value
for additional
161
reset options
see CV64
192 – 231
192
0 – 255
128
00 – 3
3
Value
0
1
0
2
0 – 255
14
Value
0
1
0
2
0
4
0
8
0
16
0
32
0
05.12.2012 12:27:07