EZ-SCAN 4000 ___________________________________________________________________________
Make sure that all the pins are straight and that the connecting surfaces are free of
oils, grease, and moisture.
CAUTION:
Do not force the cable connector into the scanner or into the vehicle
computer connection.
Push the scanner cable and vehicle connectors together firmly.
NOTE:
Make sure the scanner cable and vehicle connectors are always properly seated during
all test procedures.
Insert the EZ-SCAN cable connector into the top of the scanner.
2.5 -

Set the Time Units for Capture Mode

The EZ-Link scanner can be set up to capture a user defined length of time while in
Capture Mode. The default setting is 1000 ms (1 sec) per frame.
To change the Capture Time, press CONFIG from the initial screen.
Use the
and
ENTER.
Use the
and
Use the
and
between 500 and 5000 ms, then press ENTER to select the choice (or press the
CONFIG Key to Cancel and return to the initial screen).
NOTE:
500 milliseconds is one-half a second, 1000 milliseconds is 1 second, and
5000 milliseconds is 5 seconds.
40
arrow keys until 2-System Config is displayed, then press
arrow keys to select 2-Capture Time, then press ENTER.
arrow keys to change Capture Time to the desired number
OPERATING INSTRUCTIONS