Preparations For Wet Grinding; Manoeuvring Via The Control Panel; Standby - Husqvarna HTC 950 RX Manuel De L'opérateur

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Operation
7.
Turn on the Mist-Cooler by turning the control (position 5 Figure 3-2, page 12) to
"ON".
8.
Switch off the Mist-Cooler by turning the control (position 5 Figure 3-2, page 12)
to "OFF" when grinding is finished.
9.
Turn the tap to the closed position when grinding is finished.
4.10

Preparations for wet grinding

Tip!
Never use a dust extractor, as it may cause blockages in the dust extractor's
suction hose.
1.
Always use liquid suction when wet grinding.
2.
Inspect the floor carefully and remove any objects sticking up, such as
reinforcement rods or bolts, and any debris that could get caught in the machine.
3.
Attach the appropriate tool to the machine, see under Fitting grinding tools, page 
25
4.
Set the handle to the working position, see Figure 4-2, page 18. 
Warning!
Only use cold water with no chemical additives.
5.
Connect the water hose to the water connection. See position 11Figure 3-1, page 
11
6.
Turn the tap on the machine on to start the water supply.
7.
Turn in the opposite direction to turn the water off.
4.11

Manoeuvring via the control panel

During manual driving, the operator pushes the machine forwards across the floor
surface and manoeuvres it via the control panel, see Figure 3-3, page 13.
Tip!
Drive the machine manually in difficult to navigate spaces.
4.11.1

Standby

To activate the machine's functions, turn the key to the right. When the key is in this
position, the Power green indicator light on the control panel is lit, indicating that the
machine is in standby mode.
28