Dibo JMB-C+ Serie Mode D'emploi page 112

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

E N
    O P E R AT I O N
Note: the high pressure valve is not mounted when you
choose a low pressure hose/reel & high pressure hose/reel.
25 T R AC K & T R AC E ( O P T I O N )
The trailer can be equipped with a tracker. The necessary information/data can
be achieved via a login on the tracker website. Also use/reed the delivered
manual of the tracker (1.780.510).
Pay attention: when you want to use the Track & Trace, first
reconnect the tracker to the battery of the trailer. This can happen
by inserting the delivered fuse of 1A in the fuse holder "F14" (in
the burner electric box) whereby the tracker will charge.
When the tracker has power supply, the tracker will attempt to connect to GPS
satellites, which will update the date and time and the device will receive the
correct settings again after which it will send all the logged data to the platform.
The SIM card must have a connection with a mobile phone network to send all
relevant data.
26 P R O F E S S I O N A L S W I TC H M O D E B AT T E RY C H A R G E R ( O P T I O N )
The trailer with track & trace will be standard equipped with a charging cable
(1.701.075) to connect any professional switch mode battery charger (1.701.210)
on the battery.
Pay attention: the battery may not be charged constantly!
The trailer (machine) may not be switched on at any
circumstances during the charging procedure!
For info: If the battery clamps are incorrectly connected, the reverse polarity
protection will ensure that the battery and charger are not damaged.
Estimated time for charging (for an empty battery): +- 20h. The charger is
designed for charging only for batteries according to the technical specification.
See also the delivered manual of the professional switch mode battery charger.
27 OV E R H E AT E D WAT E R F U N C T I O N ( O P T I O N )
The overheated water function can be activated by holding the joystick up
during 3 seconds in the temperature setting menu. On the screen appears
function overheated water switched on. This can be deactivated by keeping the
joystick down for 3 seconds in the temperature setting menu. On the screen,
the measured overheated water temperature appears and the temperature
setting. The machine regulates the temperature to a fixed temperature suitable
for developing superheated water.
28 T E M P E R AT U R E C O N T R O L L E R ( O P T I O N A L )
The temperature controller ensures that the output temperature remains
constant, regardless fluctuations in the temperature of the supplied water
(within the limits of the system). This system also ensures optimum load of the
burner, which benefits the emissions and lifespan of the burner (less circuitry).
Also the water heating at cold start will work out faster.
29 D E S C A L I N G C O I L ( O P T I O N A L )
The descaling coil is an additional accessory and is located around the high-
pressure hose at the entrance to the burner boiler. This coil need to prevent
possible lime formation in the supply hose and in the burner coil.
The coil gives a signal that changes the shape of the lime minerals in the water.
As a result, small groups are formed that can no longer attach themselves to the
components and will therefore flush out of the pipes/hoses. This coil extends
the service life of the components exposed to limescale deposits.
DiBO 20

Publicité

Table des Matières
loading