NOZZLE MAINTENANCE

See Figure 15-16
Excessive pump pressure (a pulsing sensation felt while
squeezing the trigger) may be the result of a clogged or
dirty nozzle.
Turn off the pressure washer and shut off the water
supply. With the surface cleaner on the ground, pull
trigger to release water pressure.
Disconnect surface cleaner from spray wand.
Remove the U-clip from the nozzle holder, then
rotate and remove the nozzle.
NOTE: Never point the spray lance at your face.
Using a straightened paper clip or nozzle cleaning
tool (not provided), free any foreign materials
clogging or restricting the nozzle.
Using a garden hose, flush debris out of nozzle by
back flushing (running the water through the nozzle
backwards or from the outside to the inside).
Place the nozzle back into the nozzle holder. Then
rotate the nozzle until it locks in place. Reinstall the
U-clip.
NOTE: Make sure the nozzles are securely in place
before using.
Reconnect the surface cleaner to the spray wand.
Turn on the water supply and start the pressure
washer.
English(Original instructions)