No commands will be accepted during repositioning but the security devices will cut in and block all movement if they go into alarm. To interrupt the
repositioning manoeuvre press the 'PROG' or 'TB' button.
COURTESY LIGHT / CH2 RADIO OUTPUT / ERROR SIGNAL MANAGEMENT
Binding posts '9','10' are linked to a C-NO relay; this can be activated by choosing the relative function through the
as follows:
Courtesy light: the contact is closed by a timer.
CH2 radio: the contact works as a second radio channel.
SL
Error signal
, the contact closes if an error is detected
Binding posts '9', '10' only give a potential free contact; this means that the courtesy light will have to be powered by an external circuit and
the contact used as a simple switch
LIMITED OPENING (PEDESTRIAN ACCESS)
SL
the sliding gate limited opening distance ranges from 1 to 9 metres, and can be set in the MOTION menu by modifying parameter 4c.
BL
HL
limited opening always effects gate 1; the limited opening space can be set (see MOTION menu on the LCD) to 1/3, half, 2/3 or
the entire opening distance for gate 1.
• If the 'open-close' mode is set for the 'TD' button (menu 'OPTIONS') activating the 'TAL' button will start the limited opening stage (only
from the completely closed position) but while the gate is opening pressing the button again will have no effect. Once the opening position
has been reached pressing the 'TAL' button will start closing after which pressing 'TAL' again will have no effect.
• If the 'open-block-close' mode is set for the 'TD' button (menu 'OPTIONS') activating the 'TAL' button will start the limited opening stage
(only from the completely closed position) pressing the button again will block the gate; pressing the button a third time will start the closing
cycle. Pressing the 'TAL' button again will have no effect.
• If an opening command is received during limited opening; the limited opening command will become a full opening command. If the FI
photocell cuts in during the closing stage you will only have partial movement in the opening direction (It reopens only for the distance it
has been closing the gate).
• Note: The limited opening command can also be given by remote control.
.