6) Safety device parameters

6a) Contact TB
• With
highlighted press PROG/OK PROG/OK
SAFETY DEVICES
• Press PROG/OK to scroll between the available choices:
- NC (NC-contact)
- 8K2 (8.2KΩ-contact)
• Press the arrow button
move to the next parameter
This option determines the status that the TB contact (NC or 8K2) will assume when it is at rest.
6b-6c) Contact FI - FS
• Press PROG/OK to scroll between the available choices:
- NC (NC-contact)
- 8K2 (8.2KΩ-contact)
• Press the arrow button
move to the next parameter.
This option determines the status (NC or 8K2) that the FI inverting photocells and the stop photocells will assume
when they are at rest.
6d) Contact CP
• Press PROG/OK to scroll between the available choices:
- NC (NC-contact)
- 8K2 (8.2KΩ-contact)
• Press the arrow button
and move to the next parameter
• Press PROG/OK to return to the main menu.
This option determines the status that the CP safety edge contact (NC or 8K2) will assume when it is at rest.
to confirm the choice eg. NC. The programmer will save the choice and
to confirm the choice eg. NC. The programmer will save the choice and
to confirm the choice eg. 8K2. The programmer will save the choice
.
EXIT
67
6a) Contact TB
C O N TA C T T B
8K2
C O N TA C T F I
NC
C O N TA C T F S
NC
6c) Contact FI-FS
C O N TA C T T B
8K2
C O N TA C T F I
NC
C O N TA C T F S
NC
6d) Contact CP
C O N TA C T F I
8K2
C O N TA C T F S
NC
C O N TA C T C P
8K2