Creating a priority circuit
You can create a priority circuit using the AG 102 changeover relay whereby the
external voltage supply has priority over the generator, see circuit diagram (fig. j,
page 13):
Item
Description
1
230 V external voltage supply
2
Vehicle electrical distribution system
3
Connection box
➤ Mount the AG 102 changeover relay in a suitable position.
➤ Disconnect the cable which links the mains input with the circuit breaker in the
electrical distribution system of the vehicle so that the connections can be made
as shown in the circuit diagram.
➤ Use a flat plug for connecting the cable to the switch.
➤ Connect A with plug-in sleeve 4 and B with plug-in sleeve 6.
➤ Connect the cable from the 230 V connection terminal of the generator to plug-
in sleeve 1 and plug-in sleeve 3.
10.8
Connecting the remote control
➤ Connect the remote control to the connection box of the generator using the
extension cable provided on the plug for the remote control (fig. g 3, page 11).
10.9
Connecting the float
➤ Connect the float from the tank to the float connection (fig. g 4, page 11).
10.10
Connecting two genarators in parallel
I
NOTE
Use only one starter battery to start both generators.
When connecting the generators, note the following:
• It is not possible to connect more than two generators in parallel.