Fault
Appliance cannot be started Switch on the appliance switch, wait 3 seconds,
Insufficient water quantity
Insufficient vacuum perfor-
mance
Insufficient cleaning result
Brush does not turn
14

Faults

Warning
Risk of damage to the appliance on ac-
count of water leakage. Drain out dirty
water and the remaining free water be-
fore working at the machine.
In case of faults that cannot be reme-
died using the table below please con-
tact the customer service.
Remedy
check charge condition of the battery.
Check fresh water level, refill tank if necessary.
Switch on "Detergent" button.
Open the dosing device for the cleaning solution.
Clean the fresh water filter.
Lower the vacuum bar.
Empty the waste water tank.
Clean the seals between waste water tank and cov-
er and check for tightness, replace if required.
Clean the vacuum lips on the vacuum bar, turn or re-
place if required
Check if the suction hose and vacuum bar are
chocked, clean if required
Check the suction hose for tightness; replace if re-
quired.
Check/set the brush contact pressure.
Check the brush type and the detergent for their suit-
ability.
Check the brushes for wear, replace if required.
Pull the safety switch towards the steering wheel.
Check if foreign matters are blocking the brush roll-
er; remove foreign matter if required.
Switch off the switch for the brush drive, wait for a
short period of time, switch the switch back on.