Technical data

General data

Field
Order designation
PUO ID number
Communication profile
(DIN 19245 part 1 and part 3)
Communication medium
Drive profile
Network topology
PROFIBUS nodes
Baud rate [kbps]
Process data words
DP user data length
Max. number of nodes
Max. cable length per bus
segment
External DC voltage supply

Operating conditions

Ambient conditions
Climate
Storage
Transport
Operation
Pollution
Degree of protection
EDK82ZAFPC−001 DE/EN/FR 7.0
Values
E82ZAFPC001
0x00DA
hex
PROFIBUS−DP−V0
RS485
"Drive technology 20" DRIVECOM profile, can be switched off
l
Without repeater: line
l
With repeater: line or tree
Slave
9.6 ... 12000 (automatic recognition)
1 ... 10 words
(16 bits per word)
4 parameter data words +
1 ... 10 process data words
l
Standard: 32 (= 1 bus segment)
l
With repeater: 125
1200 m (depending on the baud rate and cable type used)
+24 V DC ±10 %, max. 80 mA
IEC/EN 60721−3−1
IEC/EN 60721−3−2
Corresponding to the data of the Lenze standard device used (see
documentation of the standard device).
EN 61800−5−1
IP20 (protection against accidental contact according to NEMA 250 type 1)
l
1K3 (−25 to +60 °C)
2K3 (−25 to +70 °C)
Degree of pollution 2