Charger Indicator - Gardol GAM-E 33/1Li Instructions D'origine

Table des Matières

Publicité

11. Charger indicator

Indicator status
Green is fl ashing
Red in on
Green is on
Red is fl ashing
Red and green are fl ashing
alternately
* For our latest prices and information please go to www.isc-gmbh.info
Anl_GAM_E_33_Li_1_SPK7.indb 27
Anl_GAM_E_33_Li_1_SPK7.indb 27
GB
Explanations and actions
Ready for use
The charger is connected to the mains and is ready for use; there is no
battery pack in the charger
Charging
The charger is charging the battery pack.
The battery is charged and ready for use.
(Charging time for 1.5 Ah battery: approx. 2 hours)
(Charging time for 2.0 Ah battery: approx. 2½ hours)
(Charging time for 2.6 Ah battery: approx. 3,25 hours)
(Charging time for 3.0 Ah battery: approx. 4 hours)
(Charging time for 4.0 Ah battery: approx. 5 hours)
(Charging time for 5.0 Ah battery: approx. 6½ hours)
Action:
Take the battery pack out of the charger. Disconnect the charger from
the mains supply.
Fault
Charging is no longer possible. The battery pack or charger is defec-
tive.
Action:
Never charge a defective battery pack.
Take the battery pack out of the charger.
Temperature fault
The battery pack is too hot (e.g. due to direct sunshine) or too cold
(below 0° C).
Action:
Remove the battery pack and keep it at room temperature (approx. 20°
C) for one day .
Should this fault still occur afterwards, the battery has undergone ex-
haustive discharge and must never be charged or used again. Take the
battery pack out of the charger.
- 27 -
30.10.2017 09:44:21
30.10.2017 09:44:21

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

34.131.25

Table des Matières