Noritz NR71-SV Guide D'installation page 5

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

• Avoid installation above gas ranges or stoves. (NR71-SV, NR66-SV)
• Avoid installation between the kitchen fan and stove. If oily
fumes or a large amount of steam are present in the installation
location, take measures to prevent the fumes and steam from
entering in the equipment. (NR71-SV, NR66-SV)
• Install in a location where the exhaust gas flow will not be
affected by fans or range hoods.
• Take care that noise and exhaust gas will not affect neighbors.
Avoid installation on common walls as the unit will make some
operational noises while it is running.
• Make sure that the location allows installation of the exhaust
vent as specified.
• For outdoor installation, use the outdoor vent cap.
If it is necessary to vent above the roof line in an outdoor instal-
lation, use high temperature sealant around the flue collar for
rain protection.
• Avoid installation where the unit will be exposed to excessive
winds.
• Before installing, make sure that the vent termination (or the
vent cap in an outdoor installation) will have the proper clear-
ances according to the National Fuel Gas Code (ANSI Z223.1).
State of California: The water heater must be braced, anchored or strapped to avoid moving during an
earthquake. Contact local utilities for code requirements in your area or call: 1-866-766-7489 and request
instructions.
The Commonwealth of Massachusetts:
1) The outdoor units (OD) can only be used if they are for summer use only.
2) The water heater can be used for hot water only and not in a combination of domestic and space
heating.
For Venting Manufacturers Requirements, see websites or phone numbers listed below:
Noritz N-Vent
CAUTION
(NR71-SV, NR66-SV)
www.noritz.com
Prohibited
Be sure to do
Prohibited
5

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Nr66-svNr71-odNr66-od

Table des Matières