Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

Installation Manual
Canada
TANKLESS GAS WATER HEATER
NR71-SV, NR66-SV
NR71-OD, NR66-OD
Potential dangers from accidents during installation and use are divided into the following three
categories. Closely observe these warnings, they are critical to your safety.
DANGER
WARNING
CAUTION
WARNING:
If the information in this manual is not followed exactly, a fire or explosion may result
causing property damage, personal injury or death.
Prohibited
Requests to Installers
• In order to use the water heater safely, read this installation manual carefully, and follow the
installation instructions.
• Failures and damage caused by erroneous work or work not as instructed in this manual are not
covered by the warranty.
• Check that the installation was done properly in accordance with this Installation Manual upon
completion.
• After completing installation, please either place this Installation Manual in a plastic pouch and
attach it to the side of the water heater (or the inside of the pipe cover or recess box if applicable),
or hand it to the customer to retain for future reference. Also, be sure to fill in all of the required
items on the warranty and to hand the warranty to the customer along with the Owner's Guide.
CERTIFIED
R
KS-09-0007
Rev. 10/09
(Indoor/Outdoor Installation)
(Outdoor Installation)
DANGER indicates an imminently hazardous situation which,
if not avoided, will result in death or serious injury.
WARNING indicates a potentially hazardous situation which,
if not avoided, could result in death or serious injury.
CAUTION indicates a potentially hazardous situation which,
if not avoided, may result in minor or moderate injury.
Disconnect
Power
CAUTION
FOR USE IN RESIDENTIAL, COMMERCIAL, OR MANUFACTURED HOME
APPLICATIONS. (NR71-OD, NR66-OD only)
Installation must conform with local codes, or in the absence of local codes, the
National Fuel Gas Code, ANSI Z223.1/NFPA 54- latest edition and/or CSA
B149.1, Natural Gas and Propane Installation Code (NSCNGPIC).
When applicable, installation must conform with the Manufactured Home Construc-
tion and Safety Standard, Title 24 CFR, Part 3280 or the Canadian Standard CAN/
CSA-Z240 MH Mobile Homes, Series M86. (NR71-OD, NR66-OD only)
Noritz America reserves the right to discontinue, or change at any
time, the designs and/or specifications of its products without notice.
Ground
NORITZ AMERICA
CORPORATION
Be sure to do

Publicité

Table des Matières
loading

Sommaire des Matières pour Noritz NR71-SV

  • Page 1 Safety Standard, Title 24 CFR, Part 3280 or the Canadian Standard CAN/ CSA-Z240 MH Mobile Homes, Series M86. (NR71-OD, NR66-OD only) Noritz America reserves the right to discontinue, or change at any KS-09-0007 time, the designs and/or specifications of its products without notice.
  • Page 2: Included Accessories

    Shape Q’ty Q’ty Remote Controller Remote Controller Cord 3m (10ft) (See p. 22) Outdoor Vent Cap Remote Controller VC4-1 (for NR71-SV) Cord 8m (26ft) VC3 (for NR66-SV) Isolation Valves (includes pressure relief valve) Recess Box Pipe Cover (PC1S) RB-600 (NR71-SV, NR71-OD)
  • Page 3: Before Installation

    Checkup • Check the fixing brackets and vent pipe yearly for damage or wear. Replace if necessary. WARNING Check the Gas Ex. For Natural Gas NR71-SV • Check that the rating plate indicates the NR71-SV correct type of gas. 180,000 BTU 25,000 BTU •...
  • Page 4: Choosing Installation Site

    (e.g., hair spray or spray detergent) are used. Ignition failures and malfunction may occur as a result. [NR71-SV, NR66-SV only] • Carbon Monoxide Poisoning Hazard. Do not install this water heater in a mobile home, recreation vehicle or on a boat.
  • Page 5 CAUTION • Avoid installation above gas ranges or stoves. (NR71-SV, NR66-SV) • Avoid installation between the kitchen fan and stove. If oily fumes or a large amount of steam are present in the installation location, take measures to prevent the fumes and steam from Prohibited entering in the equipment.
  • Page 6: Installation Clearances

    Install in accordance with relevant building and mechanical codes, as well as any local, state or national regulations, or in the absence of local and state codes, to the National Fuel Gas Code ANSI Z223.1/NFPA 54 – latest edition. In Canada, see NSCNGPIC for detailed requirements. [ For NR71-SV, NR66-SV ] Item Check Illustration •...
  • Page 7 [ For NR71-OD, NR66-OD ] Illustration Item Check • Maintain the following clearance from both combustible and non-combustible materials. 600mm (24") (300mm (12")) * ( ) indicates the distance when installing a heat insulat- or more ing board (incombustible material other than metal, with thickness of 2.5mm (0.1") or more) or "section of build- ing effectively finished with incombustible material."...
  • Page 8 Clearance Requirements from Vent Terminations to Building Openings * All clearance requirements are in accordance with ANSI Z21.10.3 and the National Fuel Gas Code, ANSI Z223.1 and in Canada, in accordance with NSCNGPIC. Vent Terminal Area Where Terminal is Not Permitted Air Supply Inlet Indoor Installation Outdoor Installation...
  • Page 9 Clearance Requirements from Vent Terminations to Building Openings * All clearance requirements are in accordance with ANSI Z21.10.3 and the National Fuel Gas Code, ANSI Z223.1 and in Canada, in accordance with NSCNGPIC. [ For NR71-SV, NR66-SV ] Maintain the following clearances to any Illustration opening in any building: •...
  • Page 10 [ For NR71-OD, NR66-OD ] Maintain the following clearances to any Illustration opening in any building: • 0.3m (1') below, 0.3m (1') horizontally from, or 0.3m (1') above any door, operable win- dow, or gravity air inlet into any building. 0.9m (3') above any forced air inlet within 3m (10').
  • Page 11 Installation Securing to the wall • The weight of the device will be applied to the wall. If the strength of the wall is not suffi- cient, reinforcement must be done to prevent the transfer of vibration. • Do not drop or apply unnecessary force to the device when installing. Internal parts may be damaged and may become highly dangerous.
  • Page 12: Vent Pipe Installation

    Vent Piping should be no longer than 0.9m (3'). • Noritz N-Vent is suggested for the vent system. • Make sure vent pipe is gas tight and will not If N-Vent is not used, a UL listed category III vent leak.
  • Page 13 (1') above any door, window, or gravity air inlet into any building per National Fuel Gas * Adapter not required when Code ANSI Z223.1/NFPA 54. using Noritz N-Vent. **0.3m (1') minimum recommended, • Slope the horizontal vent 1/4" downwards but not required. Avoid installing for every 300m (12") toward the termination.
  • Page 14: Combustion Air

    Supply combustion air to the units as per the National Fuel Gas Code, ANSI Z223.1 and Combustion Air in Canada, in accordance with NSCNGPIC. • Provide two permanent openings to allow circulation of combustion air. 225mm (9") • Make each opening 180 square inches if they provide indoor air, and 100 square inches for 500mm outdoor air.
  • Page 15: Gas Piping

    Outlet D: 25' (Use 30'), 25,000 Btuh requires 1/2" (25,000 Btuh) (65,000 Btuh) Section 3: 45' (Use 50'), 175,000 Btuh requires 1" Outlet E: 25' (Use 30'), 180,000 Btuh requires 3/4" (NR71-SV (-OD)) 140,000 Btuh requires 3/4" (NR66-SV (-OD)) Natural Gas Meter Section 4: 45' (Use 50'), 355,000 Btuh requires 1-1/4"...
  • Page 16 Gas Line Sizing for a Noritz Gas Water Heater Adapted from UPC 1997 Maximum Natur Natural Gas Delivery Capacity in Cubic Feet per Hour (0.60 Specific Gravity, 0.5" WC Pressure Drop) Length in Feet Pipe Size 100' 125' 1/2" 3/4"...
  • Page 17: Water Piping

    Installation and service must be performed by a qualified plumber. In the Water Piping Commonwealth of Massachusetts, this product must be installed by a licensed plumber or gas fitter in accordance with the Massachusetts Plumbing and Fuel Gas Code 248 CMR Sections 2.00 and 5.00. Observe all applicable codes. This appliance is suitable for potable water and space heating applications.
  • Page 18 Supply water piping Hot water piping • Do not use PVC, iron, or any piping which has been • Do not use lead, PVC, iron or any piping which treated with chromates, boiler seal or other chemicals. has been treated with chromates, boiler seal or •...
  • Page 19: Water Treatment

    Noritz Scale Shield, that reduce the amount of scale deposits. Refer to the below tables for sug- gested treatment and maintenance measures to be taken based on the water hardness level. Damage to the water heater as a result of water in excess of 12 gpg (200 mg/L) of hardness is not covered by the Noritz America Limited Warranty.
  • Page 20: Plumbing Applications

    (Model L6006A or L6006C) Combination Potable Water and Space Heating System Notes: 1. Noritz recommends the use of an Isolation Kit with the installation. These kits include an integrated shut-off and serv- ice valve with unions and a pressure relief valve.
  • Page 21: Electrical Wiring

    Note: When installing the water heater outdoors, either use the Ground included power cord with an approved outdoor outlet or hard wire the appliance. (NR71-SV,NR66-SV only.) CAUTION Electrostatic discharge can affect electronic components. Take precautions to prevent electrostatic discharges from personnel or hand tools during the water heater installation and servicing to protect...
  • Page 22: Remote Controller

    Install the remote controller according to the instructions in the Installation Guide (p. 28). • The NR71-SV can be programmed so that it will default to one of three temperatures (60°C, 55°C, 50°C (140°F, 130°F, 122°F)) when the temperature selection wire is not connected. To change the default temperature, connect the temperature selection wire as shown in the below diagram.
  • Page 23 Connecting Remote Controller Cord to Unit • Keep the remote controller cord away from the freeze prevention heaters in the unit. • Tie the redundant cord outside the water heater. Do not put the extra length inside the equipment. • The remote controller cord can be extended up to 90m (300') with 18AWG wire. •...
  • Page 24: Trial Operation

    Periodically check the following to ensure proper Maintenance operation of the water heater. • The venting system must be examined periodically by a qualified service technician to check for any leaks or corrosion. • The burner flame must be checked periodically for a proper blue color and consistency. •...
  • Page 25: Lighting Instructions

    WARNING A fire or explosion may result if these instructions are not followed, which may cause lose of life, personal injury or property damage. Lighting Instructions This water heater does not have a pilot. It is equipped with an ignition device that automatically lights the burner.
  • Page 26: Dimensions

    Dimensions NR71-SV < mm [inch] > (VIEW FROM TOP) 338mm[13.3"] 267mm[10.5"] 199mm[7.8"] 158mm[6.2"] 36mm[1.4"] 10mm[0.4"] 170mm[6.7"] 4-Ø13mm[Ø0.5"] 76mm[3"] 350mm[13.8"] 2-6.5 x 13mm[0.3" x 0.5"] HOT WATER OUTLET(3/4") GAS INLET (3/4") 334mm[13.1"] OBLONG HOLE COLD WATER INLET(3/4") Ø100mm[Ø4"] 120mm[4.7"] WIRING THROUGHWAYS 28mm[1.1"]...
  • Page 27 NR66-SV 338mm [13.3"] (VIEW FROM TOP) 255mm [10.0"] 178mm [7.0"] 109mm [4.3"] 37mm [1.5"] 170mm [6.7"] 10mm [0.4"] 4- 13mm [ 0.5"] 76mm [3"] 2-6.5 x 13mm [0.3" x 0.5"] 350mm [13.8"] HOT WATER OUTLET(3/4") OBLONG HOLE GAS INLET (3/4") 334mm [13.1"] COLD WATER INLET(3/4") 120mm [4.7"]...
  • Page 28 Remote Controller RC-7649M carefully before carrying out installation. Installation Guide NORITZ AMERICA CORPORATION Note Do not connect power to the water heater before the remote controller has been properly installed. Recommended installation location of the remote controller is in a bathroom.
  • Page 29 Installation 1. Apply Wall Packing to the rear side of the 3. Remove the cover of the remote control, remote controller. mark the location of the screw holes, and drill holes for the wall anchors. 2. Connect the remote controller wires to the 4.
  • Page 30 Installing the Remote Controller Outdoor Junction Box 5. Slide the box nut over the remote controller 1. Insert the remote controller wires through the wires and screw it onto the wall pipe. wall pipe and secure the wall pipe to the remote controller.
  • Page 33: Chauffe-Eau À Gaz Sans Cuve

    24 CFR, Part 3280 ou la norme canadienne CAN/CSA-Z240 MH Maisons mobiles, Série M86. [ Pour NR71-OD, NR66-OD uniquement ] Noritz America se réserve le droit d'arrêter ou de modifier à tout moment et sans préavis la conception et/ou les spécifications de ses produits.
  • Page 34: Accessoires Inclus

    Cordon de Télécommande télécommande (Voir p. 23) 3m (10') Bouchon d’évent Cordon de extérieur télécommande VC4-1 (Le NR71-SV) 8m (26') VC3 (Le NR66-SV) Clapets d’isolement (comprenant une soupape de sûreté de la pression) Boîtier encastr RB-600 Couvre-tuyau (PC1S) (Uniquement pour...
  • Page 35: Avant L'installation

    10.5 0.55 2.25 • Vérifiez que la conduite d’alimentation de gaz est calibrée pour 180,000 Btuh pour le NR71-SV, NR71-OD. (140,000 Btuh pour le NR71-SV, NR71-OD.) Vérifiez l’alimentation • L’alimentation requise est de 120VCA, à 60Hz. Une tension incorrecte pourrait provoquer un incendie ou une électrocution.
  • Page 36 Des défaillances ou dysfonctionnement de l’allumage pourraient en résulter. [ Pour NR71-SV, NR66-SV uniquement ] • Risque d’empoisonnement au monoxyde de carbone N’installez pas le chauffe-eau dans un mobile home, une caravane ou sur un bateau.
  • Page 37 (NR71-SV, NR66-SV) • Installez dans un endroit où le flux du gaz d’échappement ne sera pas affecté par des ventilateurs ou des hottes.
  • Page 38: Dégagement Pour L'installation

    à la norme ANSI Z223.1/NFPA 54 - dernière édition du National Fuel Gas Code. Au Canada, voir NSCNGPIC pour le détail des exigences. [ Le NR71-SV, NR66-SV] Rubrique Vérification Illustration •...
  • Page 39 [ Le NR71-OD, NR66-OD ] Rubrique Vérification Illustration • Maintenez le dégagement suivant des matériels com- bustibles et non-combustibles. Au moins * ( ) indique la distance lors de l'installation d'une plaque 600mm (300mm) de calorifugeage (matière incombustible autre que le 24"...
  • Page 40: Exigences De Dégagement Des Bouches De L'évent Par Rapport Aux Ouvertures Du Bâtiment

    Exigences de dégagement des bouches de l’évent par rapport aux ouvertures du bâtiment * Toutes les exigences de dégagement sont conformes à la norme ANSI Z21.10.3 et le National Fuel Gas Code, ANSI Z223.1 et au Canada NSCNGPIC. Bouche de l’évent Zone où...
  • Page 41 Exigences de dégagement des bouches de l’évent par rapport aux ouvertures du bâtiment * Toutes les exigences de dégagement sont conformes à la norme ANSI Z21.10.3 et le National Fuel Gas Code, ANSI Z223.1 et au Canada NSCNGPIC. [ Le NR71-SV, NR66-SV ] Maintenez les dégagements suivants par Illustration rapport aux ouvertures d’un bâtiment :...
  • Page 42 [ Le NR71-OD, NR66-OD ] Maintenez les dégagements suivants par Illustration rapport aux ouvertures d’un bâtiment : • 0.3m (1') dessous, 0.3m (1') horizontalement à partir de, ou 0.3m (1') au dessus d'une porte, fenêtre utilisable ou entrée d'air dans un bâtiment. 0.9m (3') au-dessus d’une entrée d’air forcée dans la limite de 3m (10').
  • Page 43: Fixation Au Mur

    Installation Fixation au mur • Le poids de l’appareil sera appliqué sur le mur. Si la force du mur n’est pas suffisante, un renforcement doit être fait pour empêcher un transfert de la vibration. • Ne laissez pas tomber ni n’usez de force inutile sur l’appareil lors de l’installation. Les pièces internes pourraient être endommagées et devenir très dangereuses.
  • Page 44: Installation Du Tuyau D'évent

    Tuyauterie de l’évent • La première section verticale à partir du haut du chauffe-eau ne doit pas être plus longue que 0.9m (3'). • Noritz N-Vent est recommandé pour le système • Assurez-vous que le tuyau d’évent est étanche de ventilation.
  • Page 45 National Fuel Gas Code ANSI Z223.1/NFPA 54. * Adaptateur inutile lors de l'utilisation de Noritz N-Vent. • Inclinez l’évent horizontal 1/4" vers le bas pour **0.3m (1') minimum recommandé, mais non nécessaire.
  • Page 46: Air Comburant

    Alimentez en air comburant les unités selon la norme ANSI Z223.1 du National Fuel Gas Air comburant Code et au Canada selon le NSCNGPIC. • Prévoyez deux ouvertures permanentes permettant la circulation de l’air comburant. 225mm (9") • Chaque ouverture doit être de 180 pouces carrés si elles fournissent l’air intérieur et 100 500mm pouces carrés pour l’air extérieur.
  • Page 47: Conduite De Gaz

    140,000 Btuh requiert 3/4" (NR66-SV (-OD)) gaz naturel **Voir la page suivante pour les tableaux de capacité du tuyau. Section 4 : 13.5m (45') (Utilisez 15m (50')),, 355,000 Btuh requiert 1 1/4" (NR71-SV (-OD)) 315,000 Btuh requiert 1 1/4" (NR66-SV (-OD))
  • Page 48 Calibrage de la canalisation de gaz pour un chauffe-eau à gaz sans cuve Noritz Adapté de UC1997 az naturel Capacité maximum de distribution du en pied cubique par heures (Gravité spécifique 0.60, Perte de pression 0.5" WC) Calibre Longueur en pieds...
  • Page 49 L'installation et l'entretien doivent être assurés par un plombier qualifié. Dans l'état du Commonwealth of Massachusetts, cet appareil doit être Conduite d’eau installé par un plombier ou un monteur d'installation au gaz agréés conformément aux sections 2.00 et 5.00 du Massachusetts Plumbing and Fuel Gas Code 248 CMR.
  • Page 50 Conduite de distribution d’eau Conduite d’eau chaude • N'utilisez pas de PVC, acier ou de tuyaux traités au • N'utilisez pas de plomb, PVC, acier ou de tuyaux traités au chromate, scellement par plomb pour chaudière ou chromate, scellement par plomb pour chaudière ou autres autres produits chimiques.
  • Page 51 Si le chauffe-eau est installé dans une application où l’eau est dure, celle-ci doit être traitée avec un adoucisseur, qui élimine la dureté ou en utilisant des agents séquestrant, comme la cartouche Noritz Scale Shield, qui diminue la quantité de dépôts calcaires. Reportez-vous aux tableaux ci-dessous pour le traitement suggéré...
  • Page 52 CHAUFFE-EAU À 2. Réglez l’aquastat sur 5°C (10°F) en dessous de la GAZ SANS CUVE température de sortie établie. 3. Noritz recommande d’utiliser un kit d’isolation avec Robinets l’installation. Ces kits comprennent un robinet de service et une soupape d’arrêt intégrés avec des raccords- unions et une soupape de sûreté...
  • Page 53: Installation Électrique

    Adressez-vous à un électricien Installation électrique qualifié pour l’installation électrique. Ne branchez pas le courant à l’unité avant que toute l’installation électrique soit achevée. Couper l’alimentation électrique Cet appareil doit être relié à la terre électriquement en conformité avec les réglementations locales ou en l’absence de réglementation locale, avec la norme ANSI 70 54 du National Fuel Gas Code.
  • Page 54 à l’extérieur, utilisez le cor- don d'alimentation fourni avec une prise extérieure approuvée ou bien procédez au raccordement électrique fixe de l’appareil. ( Pour NR71-SV, NR66-SV uniquement ) ATTENTION La décharge électrostatique peut avoir une incidence sur les composants électroniques. Prenez des mesures pour empêcher les décharges électrostatiques du personnel ou des outils à...
  • Page 55: Télécommande

    Installez la télécommande selon les instructions dans le Guide d’installation (p. 29). • Le NR71-SV peut être programmé de sorte qu’il revienne au réglage par défaut d’une des trois températures (60, 55, 50°C (140, 130, 122°F)) lorsque le câble de sélection de température n’est pas branché.
  • Page 56: Raccordement Du Cordon De Télécommande À L'unité

    Raccordement du cordon de télécommande à l’unité • Eloignez le cordon de télécommande des chauffages en prévention du gel dans l’unité. • Attachez le cordon d’alimentation qui dépasse à l’extérieur du chauffe-eau. Ne placez pas de longueur superflue dans l’équipement. •...
  • Page 57: Test De Fonctionnement

    Vérifiez régulièrement les points suivants pour Maintenance garantir un bon fonctionnement du chauffe-eau. • Le système de ventilation doit être examiné régulièrement par un technicien de service qualifié pour vérifier les fuites ou la corrosion. • La flamme du brûleur doit être vérifiée régulièrement pour une couleur bleue et une consistance adéquates. •...
  • Page 58: Instructions D'allumage

    AVERTISSEMENT Le non respect de ces instructions peut être à l'origine d'un incendie ou d'une explosion pouvant provoquer des blessures corporelles ou mortelles, ou des dégâts matériels. Instructions d’allumage Ce chauffe-eau ne comporte pas de veilleuse. Il est équipé d’un dispositif d’allumage qui allume automatiquement le brûleur.
  • Page 59 Dimensions NR71-SV < mm [inch] > 338mm[13.3"] (VUE À PARTIR DE DESSUS) 267mm[10.5"] 199mm[7.8"] 158mm[6.2"] 36mm[1.4"] 10mm[0.4"] 170mm[6.7"] 4-Ø13mm[Ø0.5"] 76mm[3"] 350mm[13.8"] Trou oblong 2-6.5 x 13mm 334mm[13.1"] [0.3" x 0.5"] Ø100mm[Ø4"] SORTIE D’EAU CHAUDE (3/4") 120mm[4.7"] ENTRÉE DE GAZ (3/4") 28mm[1.1"]...
  • Page 60 NR66-SV (VUE À PARTIR DE DESSUS) 338mm [13.3"] 255mm [10.0"] 178mm [7.0"] 109mm [4.3"] 37mm [1.5"] 170mm [6.7"] 10mm [0.4"] 4- 13mm [ 0.5"] 76mm [3"] Trou oblong 350mm [13.8"] SORTIE D’EAU CHAUDE (3/4") 2-6.5 x 13mm [0.3" x 0.5"] ENTRÉE DE GAZ (3/4") 334mm [13.1"] ENTRÉE D’EAU FROIDE(3/4")
  • Page 61: Pour Les Installateurs

    Télécommande RC-7650M d’installation avant de procéder à l’installation. Guide d’installation NORITZ AMERICA CORPORATION Remarque Ne branchez pas l’alimentation au chauffe-eau avant que la télécommande ne soit correctement installée. Il est recommandé d'installer la télécommande dans la salle de bain. Liste des pièces incluses Câble de raccordement...
  • Page 62 Installation 3. Retirez le couvercle de la télécommande, 1. Appliquez la garniture du mur derrière la marquez l’emplacement des trous de vis et télécommande. 2. Raccordez les câbles de la télécommande au percez les trous pour les ancrages pour mur. cordon de télécommande distinct.
  • Page 63: Installation De La Boîte De Dérivation Extérieure De La Télécommande

    Installation de la boîte de dérivation extérieure de la télécommande 5. Faites glisser l’écrou de la boîte par-dessus 1. Insérez les câbles de la télécommande à les câbles de la télécommande et vissez-le travers le tuyau du mur et fixez-le à la dans le tuyau du mur.

Ce manuel est également adapté pour:

Nr66-svNr71-odNr66-od

Table des Matières