Maintain the following clearances to any
• 0.3m (1') below, 0.3m (1') horizontally from,
or 0.3m (1') above any door, operable win-
dow, or gravity air inlet into any building.
0.9m (3') above any forced air inlet within 3m
(10').
• 0.3m (1') below, 0.3m (1') horizontally from,
or 0.3m (1') above any door, operable
window, or gravity air inlet into any building.
0.9m (3') above any forced air inlet within
3m (10').
(recess box installation with cover removed)
* For Installations in Canada, clearances are as follows: To windows, doors, & gravity air inlets: 900mm (36").
To forced air inlets: 1.8m (6').
10
opening in any building:
Illustration
0.3m (1')
0.3m (1')
0.3m (1')
0.9m (3')
0.3m
0.3m (1')
(1')
0.3m (1')
0.9m (3')